S'abonner

Minimally invasive fixation of type B and C interprosthetic femoral fractures - 02/09/13

Doi : 10.1016/j.otsr.2013.01.011 
M. Ehlinger , J. Czekaj, P. Adam, D. Brinkert, G. Ducrot, F. Bonnomet
 Department of Orthopaedics and Trauma Surgery De Hautepierre Hospital, Strasbourg University Hospital Group, 1, avenue Molière, 67098 Strasbourg cedex, France 

Corresponding author. Tel.: +33 3 88 12 77 19; fax: +33 3 88 12 77 13.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

Interprosthetic femoral fractures are rare and raise unresolved treatment issues such as the length of the fixation material that best prevents secondary fractures. Awareness of the advantages of locked-plate fixation via a minimally invasive approach remains limited, despite the potential of this method for improving success rates.

Hypothesis

Femur-spanning (from the trochanters to the condyles) locked-plate fixation via a minimally invasive approach provides high healing rates with no secondary fractures.

Materials and methods

From January 2004 to May 2011, all eight patients seen for interprosthetic fractures were treated with minimally invasive locked-plate fixation. Mean time since hip arthroplasty was 47.5months and mean time since knee arthroplasty was 72.6months. There were 12 standard primary prostheses and four revision prostheses; 11 prostheses were cemented and a single prosthesis showed femoral loosening. Classification about the hip prostheses was Vancouver B in one patient and Vancouver C in seven patients; about the knee prosthesis, the fracture was SoFCOT B in three patients and SOFCOT C in five patients, and a single fracture was SoFCOT D. Minimally invasive locking-plate fixation was performed in all eight patients, with installation on a traction table in seven patients.

Results

Healing was obtained in all eight patients, after a mean of 14weeks (range, 12–16weeks). One patient had malalignment with more than 5° of varus. There were no general or infectious complications. One patient died, 32months after surgery. The mean Parker-Palmer mobility score decreased from 6.2 pre-operatively to 2.5 at last follow-up. Early construct failure after 3weeks in one patient required surgical revision. There was no change in implant fixation at last follow-up. No secondary fractures were recorded.

Discussion

In patients with type B or C interprosthetic fractures, femur-spanning fixation not only avoids complications related to altered bone stock and presence of prosthetic material, but also decreases the risk of secondary fractures by eliminating stress riser zones. The minimally invasive option enhances healing by preserving the fracture haematoma. Thus, healing was obtained consistently in our patients, with no secondary fractures, although the construct failed in one patient.

Level of evidence

Level IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Femoral fracture, Interprosthetic fracture, Periprosthetic fracture, Internal fixation, Locked-plate, Minimally invasive


Plan


© 2013  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 5

P. 563-569 - septembre 2013 Retour au numéro
Article précédent Article précédent
  • Infection as a cause of primary total hip arthroplasty revision and its predictive factors
  • N. Reina, C. Delaunay, P. Chiron, N. Ramdane, M. Hamadouche, the Société française de chirurgie orthopédique et traumatologique e
| Article suivant Article suivant
  • Anterior cruciate ligament tear during the menstrual cycle in female recreational skiers
  • N. Lefevre, Y. Bohu, S. Klouche, J. Lecocq, S. Herman

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.