S'abonner

Relation between lower extremity alignment and proximal femur anatomy. Parameters during total hip arthroplasty - 02/09/13

Doi : 10.1016/j.otsr.2013.02.006 
M. Ollivier, S. Parratte , L. Lecoz, X. Flecher, J.-N. Argenson
 Motion research and musculo-skeletal institute, Southern Teaching Hospital Center, Sainte-Marguerite Hospital, 270, boulevard Sainte-Marguerite, 13009 Marseille, France 

Corresponding author. Tel.: +33 491 745 011; fax: +33 491 745 625.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Background

Lower extremity alignment correlates with native femoral offset. Eventual impact of the change in femoral offset induced by total hip arthroplasty (THA) on lower extremity alignment has not been documented.

Hypothesis

THA significantly changes lower extremity alignment, and the change correlates with the change in femoral offset.

Materials and methods

We conducted a prospective study of 200 patients with primary hip osteoarthritis or avascular femoral head necrosis who underwent cementless THA. Pre-operative computed-tomography templating was performed and the femoral component was then custom-manufactured to replicate the native femoral anatomy. Mean age was 58 years (range, 28–83 years). Before and at least two years after THA, two observers who were not involved in the surgical procedures used standing antero-posterior long-leg radiographs to determine the mechanical axis of the lower-limb (hip-knee-ankle [HKA] angle), femoral offset, neck-shaft angle (NSA), and lower-limb length discrepancy (LLLD).

Results

Mean values pre-operatively and at last follow-up were as follows: HKA angle, 179.2°±3.9° (range, 170.5° to 190.5°) and 177.7°±3.5°(range, 173° to 187°); LLLD, −0.7mm (range, –30mm to+25mm) and+5.1mm (range, –7mm to+21mm); NSA, 134°±7.5° (range, 100° to 124°) and 135°±4.2° (range, 124° to 146°); and femoral offset, 42±7.8mm (range, 24mm to 68mm) and 49±7.5mm (range, 33mm to 70mm). Although THA significantly altered lower-limb alignment, univariate and multivariate analyses showed no significant association between the change in HKA angle and the change in femoral offset.

Discussion

Lower-limb alignment was significantly affected by THA, although the HKA angle changes were small. The small impact of THA on HKA angle values may be ascribable to efforts aimed at replicating the native femoral offset during arthroplasty, as well as to the limited sample size and to potential measurement errors related to the small size of the changes. Our results suggest that, provided careful attention is directed to replicating the native femoral offset, THA in patients with limited pre-operative anatomical abnormalities may have no major impact on the biomechanical parameters of the ipsilateral knee.

Level of evidence

Level III, prospective diagnostic study.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, Femoral offset, Lower extremit alignment, Adult, Biomechanics


Plan


© 2013  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 5

P. 493-500 - septembre 2013 Retour au numéro
Article précédent Article précédent
  • Contents
| Article suivant Article suivant
  • The lateral view head-neck index (LVHNI): A diagnostic tool for the sequelae of slipped capital femoral epiphysis
  • J. Murgier, P. Chiron, E. Cavaignac, A. Espié, X. Bayle-Iniguez, B. Lepage

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.