S'abonner

Comparative Safety Analysis of Surgical Smoke From Transurethral Resection of the Bladder Tumors and Transurethral Resection of the Prostate - 02/09/13

Doi : 10.1016/j.urology.2013.05.028 
Chen Zhao a, Myung Ki Kim b, Hyung Jin Kim b, Sang Kyi Lee c, Youn Jo Chung d, Jong Kwan Park b,
a Department of Urology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, and Shanghai Institute of Andrology, Shanghai, China 
b Department of Urology, Medical School, and Institute for Clinical Medicine, Chonbuk National University and Biomedical Research Institute and Clinical Trial Center of Medical Device of Chonbuk National University Hospital, Jeonju, South Korea 
c Department of Anesthesiology, Medical School, and Institute for Clinical Medicine, Chonbuk National University and Biomedical Research Institute and Clinical Trial Center of Medical Device of Chonbuk National University Hospital, Jeonju, South Korea 
d Center for University-wide Research Facilities, Chonbuk National University, South Korea 

Reprint requests: Jong Kwan Park, M.D., Department of Urology, Medical School, Chonbuk National University, Jeonju, South Korea.

Abstract

Objective

To analyze the gas generated from the transurethral resection of the prostate (TURP) and transurethral resection of bladder (TURB) tumor.

Methods

Thirty-six smoke samples were collected from a continuous irrigation suction system during the TURP and the TURB. Then, they were subdivided into 2 groups: the group I (n = 18; gases generated from the TURP) and the group II (n = 18; gases generated from the TURB). We performed qualitative and quantitative analysis of the samples on gas chromatography/mass spectrometry.

Results

A more diverse type of gas was generated from the TURB as compared with the TURP. A further quantitative analysis was performed for 7 of 16 gases and 13 of 39 gases in the group I and group II, respectively. This showed that there was no significant difference in the concentration of propylene (propylene: 148.36 ± 207.72 ug/g vs 96.956 ± 135.138 ug/g) and 1-pentene (5137.08 ± 2935.48 ug/g vs 4478.259 ± 5787.351 ug/g) between the TURP and the TURB (P >.05).

Conclusion

Our results showed that 39 and 16 types of gases were generated from the TURB and the TURP, respectively. There were differences in the types of gases between benign hypertrophic prostate and malignant bladder tumor tissues. This indicates that electrosurgery of malignant tissue is possibly more hazardous to those who are involved in the surgical operation.

Le texte complet de cet article est disponible en PDF.

Plan


 Financial Disclosure: The authors declare that they have no relevant financial interests.
 Funding Support: This study was supported by grant from Clinical Trial Center of Chonbuk National University Hospital (2012) granted from Ministry of Health and Welfare, Republic of Korea (A091220).


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 82 - N° 3

P. 744.e9-744.e14 - septembre 2013 Retour au numéro
Article précédent Article précédent
  • BRL37344, a ?3-adrenergic Receptor Agonist, Decreases Nerve-evoked Contractions in Human Detrusor Smooth Muscle Isolated Strips: Role of BK Channels
  • Serge A.Y. Afeli, Eric S. Rovner, Georgi V. Petkov
| Article suivant Article suivant
  • Urinary Proteome Analysis in Patients With Stable SFU Grade 4 Ureteropelvic Junction Obstruction Differs From Normal
  • Hrair-George O. Mesrobian, John V. Kryger, Travis W. Groth, Gabriel E. Fiscus, Shama P. Mirza

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.