Achieving Targeted Pulse Oximetry Values in Preterm Infants in the Delivery Room - 23/07/13

Doi : 10.1016/j.jpeds.2013.01.010 
Bheru Gandhi, MD, Wade Rich, RRT , Neil Finer, MD
Division of Neonatology, University of California San Diego Medical Center, San Diego, CA 

Reprint requests: Wade Rich, RRT, CCRC, Division of Neonatology, UCSD Medical Center, 402 Dickinson Street, MPF 1-140, #8774, San Diego, CA 92103.

Abstract

Objective

To determine whether resuscitation teams can better maintain newborn transitional oxygen saturation (SpO2) values within a prespecified target range using a graphical display of the targets and real-time SpO2 data compared with using only numerical oximeter values.

Study design

Preterm neonates were enrolled in this prospective cohort evaluation of a change in practice. The Transitional Oxygen Targeting System (TOTS) plots real-time SpO2 values in relation to 10th and 50th percentile SpO2 curves, which provides a visual target. After introduction of the TOTS, the resuscitation team adjusted the fraction of inspired oxygen to maintain the SpO2 within the target range, and before its use neonates were resuscitated in attempt to target normal transitional SpO2 values without using the TOTS monitor. Duration of time within 10th-50th percentile values was compared between 2 cohorts, children evaluated with the TOTS and those not evaluated with the TOTS (controls).

Results

A total of 40 infants were enrolled, including 20 prospectively evaluated with the TOTS and 20 controls. Mean gestational age, birth weight, total resuscitation time, duration of supplemental oxygen administration, changes in oxygen concentration, and respiratory support provided were similar in the 2 groups. The TOTS cohort spent 52% of time within the target range; the control cohort, 37% (P = .03).

Conclusion

SpO2 values were maintained within a specified target range for significantly longer in preterm neonates resuscitated using the TOTS display compared with those resuscitated without TOTS.

Le texte complet de cet article est disponible en PDF.

Keyword : FiO2, GA, NRP, ROAR, SpO2, TOTS


Plan


 The authors declare no conflicts of interest.


© 2013  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 163 - N° 2

P. 412-415 - août 2013 Retour au numéro
Article précédent Article précédent
  • Enteral Feeding during Indomethacin and Ibuprofen Treatment of a Patent Ductus Arteriosus
  • Ronald Clyman, Andrea Wickremasinghe, Nami Jhaveri, Denise C. Hassinger, Joshua T. Attridge, Ulana Sanocka, Richard Polin, Maria Gillam-Krakauer, Jeff Reese, Mark Mammel, Robert Couser, Neil Mulrooney, Toby D. Yanowitz, Matthew Derrick, Priya Jegatheesan, Michele Walsh, Alan Fujii, Nicolas Porta, William A. Carey, Jonathan R. Swanson, Ductus Arteriosus Feed or Fast with Indomethacin or Ibuprofen (DAFFII) Investigators ?
| Article suivant Article suivant
  • Effects of Different Complementary Feeding Regimens on Iron Status and Enteric Microbiota in Breastfed Infants
  • Nancy F. Krebs, Laurie G. Sherlock, Jamie Westcott, Diana Culbertson, K. Michael Hambidge, Leah M. Feazel, Charles E. Robertson, Daniel N. Frank

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.