EuroSCORE II Versus Additive and Logistic EuroSCORE in Patients Undergoing Percutaneous Coronary Intervention - 18/07/13

Doi : 10.1016/j.amjcard.2013.03.032 
Davide Capodanno, MD, PhD a, b, , Fabio Dipasqua, MD a, Carmelita Marcantoni, MD c, Margherita Ministeri, MD a, Luca Zanoli, MD, PhD d, Stefania Rastelli, MD d, Gaetano Romano, MD a, Maria Sanfilippo, MD a, Corrado Tamburino, MD, PhD a, b
a Cardiovascular Department, Ferrarotto Hospital, Catania, Italy 
b ETNA Foundation, Catania, Italy 
c Division of Nephrology, Cannizzaro Hospital, Catania, Italy 
d Department of Internal Medicine, University of Catania, Catania, Italy 

Corresponding author: Tel: (+39) 0957436202; fax: (+39) 095362429.

Abstract

The aim of the present study was to externally validate the European System for Cardiac Operative Risk Evaluation (EuroSCORE) II (ESII) in patients undergoing percutaneous coronary intervention (PCI) and to compare its performance with that of its previously released versions, named additive (addES) and logistic EuroSCORE (logES). A total of 537 patients undergoing PCI were analyzed by different measurements of discrimination, calibration, and global accuracy. A significant gradient in all-cause mortality was seen with all the models at 30 days, 1 year, and 5 years, with the exception of the ESII at 30 days. The ESII had the lowest area under the receiver operating characteristic curve at all time points compared with its previous version, being 0.83 (vs 0.90 for both addES and logES) at 30 days, 0.75 (vs 0.82 for both addES and logES) at 1 year, and 0.69 (vs 0.77 for addES and 0.76 for logES) at 5 years. However, the ESII displayed a better calibration than the logES at 30 days, whereas both scores were miscalibrated at 1 and 5 years. The Brier score displayed similar global accuracy between the ESII and logES. In conclusion, the ESII is better calibrated than the logES at 30 days but does not represent a step forward in discrimination and global accuracy compared with its previous versions for predicting early- and long-term mortality of patients undergoing PCI.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 329 for disclosure information.


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 112 - N° 3

P. 323-329 - août 2013 Retour au numéro
Article précédent Article précédent
  • Comparison of First- and Second-Generation Drug-Eluting Stents in Saphenous Vein Grafts Used as Aorto-Coronary Conduits
  • Charis Costopoulos, Azeem Latib, Toru Naganuma, Alessandro Sticchi, Alaide Chieffo, Filippo Figini, Mauro Carlino, Matteo Montorfano, Charbel Naim, Masanori Kawaguchi, Francesco Giannini, Antonio Colombo
| Article suivant Article suivant
  • Comparison of Functional Recovery Following Percutaneous Coronary Intervention for ST Elevation Myocardial Infarction in Three Age Groups (<70, 70 to 79, and ?80 Years)
  • Ellen C. Christiansen, Kelly K. Wickstrom, Timothy D. Henry, Ross F. Garberich, Stephanie C. Rutten-Ramos, David M. Larson, Elizabeth Z. Grey, Norma L. Thiessen, Robert G. Hauser, Marc C. Newell

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.