Cystoscope flexible à gaine stérile à usage unique : impact organisationnel et économique et sécurité bactériologique - 30/03/13

Doi : 10.1016/j.purol.2013.01.013 
A.-C. Coste a, , A. Ruffion a, E. Lechevallier b, M. Devonec a, P. Paparel a, D. Champetier a, M. Vinet a, E. Adam a, P.-E. Briant a, C. De Vendin a, C. Coulange b, V. Delaporte b, S. Gaillet b, P.-O. Faïs b, A. Monges b, V. Arnoux b, X. Armoiry c, S. Gardes d, S. Bin c, G. Karsenty b
a Service de chirurgie urologique, centre hospitalier Lyon Sud, hospices civils de Lyon, bâtiment 3C, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France 
b Service de chirurgie urologique et de transplantation, hôpital de la Conception, AP–HM, 147, boulevard Baille, 13005 Marseille, France 
c Délégation à la recherche clinique et à l’innovation (DRCI), hospices civils de Lyon, commission du médicament et des dispositifs médicaux stériles, avenue du Doyen-Lépine, 69500 Bron, France 
d Service d’hygiène hospitalière, centre hospitalier Lyon Sud, hospices civils de Lyon, bâtiment 3B, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 1
Vidéos 0
Autres 0

Résumé

But

La législation française n’autorisant pas la désinfection de bas niveau pour les endoscopies des cavités stériles, évaluer l’impact économique et organisationnel et la sécurité bactériologique du cystoscope flexible à gaine stérile à usage unique (CFGSUU) comparativement aux cystoscopes flexibles standards (CFS) dans deux CHU français.

Patients

Étude prospective bi-centrique, ayant comparé une période d’utilisation du CFGSUU et une période d’utilisation du CFS dans chaque CHU. Deux cent cinq patients ont été inclus et répartis dans chaque groupe. Une analyse détaillée des durées de procédures et des coûts a été réalisée dans les deux techniques ainsi qu’une analyse descriptive des taux d’infections urinaires. Un test d’étanchéité des gaines après leur utilisation était réalisé.

Résultats

La durée d’installation du matériel était supérieure dans le groupe gaine : 16,2minutes versus 10,9 dans le groupe standard. La durée moyenne de désinfection était significativement moindre dans le groupe gaine : gain de temps de 53,8minutes comparé au groupe standard ; 99,01 % des gaines testées après utilisation étaient étanches avec des taux d’infections urinaires similaires dans les deux groupes. Le coût moyen d’une cystoscopie à gaine était inférieur au groupe standard, de façon significative à Lyon et non significative à Marseille. La différence de coût était significative dans les deux centres en faisant varier les prix des gaines et l’activité des services.

Conclusion

Les CFGSUU permettaient une économie significative sur la durée de désinfection, les coûts de consommables et les dépenses de personnels, tout en assurant aux patients une sécurité bactériologique comparable au CFS.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose

To assess both economical and organizational impact as well as bacteriologic safety of a flexible cystoscope with sterile disposable sheath (FCSDS) compared to standard flexible cystoscopy (SFC) in two French urologic academic units.

Patients

Two-center prospective study, comparing the use of the FCSDS to the SFC on two consecutive periods of time. Two hundred and five patients were included and divided into each group. Duration procedures and costs were analysed in the two techniques. The urinary tract infection rate was also described. A dedicated sheaths leaks test after use was performed systematically.

Results

The preparation time of the fibroscope was longer for the sheathed cystoscopy group: 16.2minutes versus 10.9minutes for the standard group. The mean duration of disinfection was significantly shorter for the sheathed cystoscopy group: 53.8minutes saved compared to the standard group; 99.01% of the tested sheaths, after their use, had no breaches. Urinary tract infections rate were similar in the two groups. The average cost of a sheathed cystoscopy compared to the standard was significantly cheaper in Lyon and almost equivalent in Marseille.

Conclusion

The FCSDS allows significant saving over the disinfection duration, consumable costs and staff costs, while ensuring patient bacteriologic safety similar to SFC.

Le texte complet de cet article est disponible en PDF.

Mots clés : Cystoscopes, Analyse économique, Techniques bactériologiques, Infection urinaire, Sécurité des équipements

Keywords : Cystoscopes, Cost analysis, Bacteriologic techniques, Urinary tract infection, Device safety


Plan


 Niveau de preuve : 2.


© 2013  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 5

P. 356-363 - avril 2013 Retour au numéro
Article précédent Article précédent
  • Prise en charge du cancer de la prostate : analyse rétrospective de 808 hommes biopsiés en France
  • O. Cussenot, F. Rozet, A. Ruffion, N. Mottet, B. Bordier, B. Malavaud, B. Meesen, H. Stoevelaar
| Article suivant Article suivant
  • Complication vasculaire d’une pyélonéphrite aiguë
  • E. Alezra, J. Fretin, F. Saint, G. Raynal

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.