S'abonner

Cicatrice de radiofréquence rénale : corrélations anatomopathologiques-tomodensitométriques chez le porc. Applications pratiques pour le suivi en imagerie - 25/01/13

Doi : 10.1016/j.purol.2012.10.004 
P. Souteyrand a, , F. Cohen b, L. Daniel b, É. Lechevallier c, C. Chagnaud a, P.H. Rolland d, M. Andre a, V. Vidal d
a Servide de radiologie, hôpital Conception, AP–HM, 147, boulevard Baille, 13385 Marseille cedex 05, France 
b Service de radiologie, hôpital Timone, AP–HM, 13005 Marseille, France 
c Service d’urologie, hôpital Conception, AP–HM, 147, boulevard Baille, 13385 Marseille cedex 05, France 
d Laboratoire de physiopathologie et de thérapie vasculaire (L2PTV), faculté de médecine, université Aix Marseille, 13005 Marseille, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 7
Vidéos 0
Autres 0

Résumé

Objectifs

Étudier la viabilité tissulaire et identifier les mécanismes d’action de la radiofréquence (RF) à partir d’une confrontation imagerie–anatomopathologie de lésions de RF rénale un mois après traitement sur un modèle porcin.

Matériels et méthodes

Vingt-quatre lésions de RF ont été réalisées sur six porcs anesthésiés (traitement aux deux pôles des deux reins) avec des aiguilles LeVeen 2cm sous guidage tomodensitométrique. Quatre semaines après traitement, les cicatrices étaient contrôlées en scanner, les reins explantés étudiés en anatomopathologie et en immuno-histochimie.

Résultats

Dix-neuf zones d’ablation (ZA) ont été étudiées en anatomopathologie et en TDM (volume, morphologie, rehaussement, cavitation) quatre semaines après RF. Une ZA abcédée était exclue des résultats ; quatre ZA n’ont pu être analysées en raison du décès précoce d’un porc pendant l’anesthésie. L’histologie des ZA décrivait un aspect hétérogène associant des zones de nécrose, d’ischémie et une surexpression de l’apoptose dans 50 % des ZA. Une nécrose des ZA était constante en histologie alors que leur rehaussement était variable voire significatif (>10UH).

Conclusion

Un mois après traitement, l’examen anatomopathologique des ZA a mis en évidence des destructions tissulaires hétérogènes par différents mécanismes sans viabilité tissulaire centrale. Si l’examen TDM post-RF à un mois est utile pour dépister des complications iatrogènes, il ne peut prédire l’efficacité du traitement car des lésions ischémiques évolutives des ZA persistent. Les contrôles initiaux doivent donc être réalisés au moins trois mois après la RF.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose

To analyze the changes in vicinal kidney parenchyma after percutaneous RFA.

Materials et methods

Twenty-four CT-guided RFA procedures were performed on six pigs using 2cm LeVeen coaxial needles. We studied volume, morphology, cavitation and enhancement of the ablation zones (AZ) before and after the procedure on contrast-injected CT-scans. The kidneys were removed four weeks later and studied in the path lab.

Results

All the procedures were successfully completed. Four weeks later, the CT-scans showed AZ that were either clearly circumscribed or with unclear borders, heterogenous areas associating necrosis and infarct tissue and mesenchyma showing a process of apoptosis around the edges. A treatment considered as incomplete on the CT-scan (presenting as an enhancement) was always associated with necrosis on the histology slides, although the necrotic areas behaved in various different ways on the CT-scan after injection of contrast medium: an enhancement of more than 10HU did not mean that no necrotic tissue was present.

Conclusion

RFA causes heterogenous tissue changes, associating necrotic and ischemic zones and an apoptotic reaction. The mechanisms of these changes and their therapeutic significance should be studied. CT-scans performed immediately after RFA procedure and one month later are not predictive of the efficacy of the treatment because an enhancement of the AZ does not mean that it is not necrotic. The value of a CT-scan performed one month after the procedure is debatable, because the tissue remodeling that occurs in the kidneys is not definitive at this time-point.

Le texte complet de cet article est disponible en PDF.

Mots clés : Radiofréquence, Scanner, Anatomopathologie, Traitement ablatif

Keywords : Radiofrequency, CT-scans, Pathology, Ablation techniques


Plan


 Niveau de preuve : 3.


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 2

P. 105-112 - février 2013 Retour au numéro
Article précédent Article précédent
  • Traitement d’une tumeur rénale et préservation néphronique impérative : étude comparative des données périopératoires et des résultats à moyen terme de la néphrectomie partielle et de la radiofréquence
  • V. Arnoux, J.-L. Descotes, C. Sengel, N. Terrier, J.-J. Rambeaud, J.-A. Long
| Article suivant Article suivant
  • Impact à long terme des complications chirurgicales sur la survie du transplant rénal
  • B. Tisserand, B. Doré, G. Touchard, F. Bridoux, J. Irani

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.