S'abonner

Plicature de la bandelette sous-urétrale comme traitement de l’incontinence urinaire d’effort persistante ou récidivante - 23/11/12

Doi : 10.1016/j.purol.2012.08.275 
C. Feyeux a, , P. Mourtialon a, b, c, A. Guyomard a, K. Astruc d, S. Douvier a, E. Delorme e
a Service de gynécologie-obstétrique, médecine fœtale et stérilité conjugale, CHU de Dijon, rue du Professeur-Marion, BP 77908, 21079 Dijon, France 
b Inserm EA 4184, centre d’épidémiologie des populations, université de Bourgogne, 7, boulevard Jeanne-d’Arc, 21000 Dijon, France 
c Faculté de médecine de Dijon, université de Bourgogne, 7, boulevard Jeanne-d’Arc, 21033 Dijon, France 
d Service antenne Bourgogne du CLIN, CHU de Dijon, rue du Professeur-Marion, BP 77908, 21079 Dijon, France 
e Service d’urologie, hopitâl privé sainte Marie, alée Saint -Jean-des-Vignes, 71100 Chalon-sur-Saône, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 2
Vidéos 0
Autres 0

Résumé

Objectifs

Évaluer la faisabilité et l’efficacité de la remise en tension des bandelettes sous-urétrales par une plicature étagée en cas d’incontinence urinaire d’effort persistante ou récidivante après pose d’une bandelette sous-urétrale (BSU).

Méthode

Étude rétrospective monocentrique incluant des patientes ayant un échec ou une récidive après pose d’une BSU. L’éligibilité était faite d’après un bilan clinique et paraclinique complet prouvant le mécanisme et la récidive de l’IUE. La chirurgie a consisté en une plicature en paletot de la bandelette.

Résultats

Dix-neuf patientes ont été incluses. Le délai moyen entre les deux chirurgies était de 23,4 mois (ds=25,5). Les résultats ont été évalués de façon subjective sur le questionnaire MHU et objectivement avec le bilan urodynamique. Le suivi moyen était de 27,2 mois (ds=37,3). La durée de l’intervention était de 30minutes. Selon le MHU, 73,7 % des patientes étaient guéries et 10,3 % étaient améliorées, IC 95 % [0,52–0,95]. La différence entre le score MHU de l’IUE avant et après la plicature était significative (p=0,0005) et passait de 2,31 (ds=0,75) à 0,56 (ds=0,92) en moyenne. Il n’y a eu aucune complication peropératoire. Il y a eu deux rétentions aiguës d’urine postopératoire avec reprise chirurgicale et section d’un fil permettant de détendre la bandelette sous-urétrale sans perdre le bénéfice de la plicature. Il n’y a pas eu d’augmentation significative des urgenturies ou de la dysurie de novo.

Conclusion

Les résultats de cette étude ont confirmé la faisabilité, l’efficacité et la morbidité faible de la remise en tension de la BSU.

Le texte complet de cet article est disponible en PDF.

Summary

Objective of the study

Feasibility and efficiency study of mesh readjustment in suburethral slings by overcoat plication in case of persisting of recurring stress urinary incontinence in patients with suburethral slings.

Methods

Retrospective and monocentric study including patients that present with a failure or recurring incontinency after suburethral slings surgery. The eligibility was evaluated after a complete clinical and paraclinical statement, proving the recurrence of the incontinence and its mechanism. Surgery consisted in a plication in an overcoat.

Results

Nineteen patients were included. The medium delay between initial surgery and the plication was 23.4months (ds=25.5). Results were evaluated subjectively by the MHU questionnaire and objectively by the urodynamic appraisal. The medium survey was 27.2months (ds=37.3). The procedure lasts about 30minutes. According to MHU, 73.7% of patients were cured and for 10.3% the symptoms were lessened. The difference in the MHU score of stress urinary incontinence before and after mesh readjustment was significant (P=0.0005) and get down from 2.31 (ds=0.75) to 0.56 (ds=0.92) as an average. There was no complication during surgery. There were two cases of postoperative acute urinary retention which were reoperated by simply cutting a thread allowing the sling to relax without losing the benefit of the plicature. There was no significant increase in urge incontinence or dysuria.

Conclusion

The results of this study confirmed the feasibility, the efficiency and the low morbidity of mesh readjustment for the suburethral sling.

Le texte complet de cet article est disponible en PDF.

Mots clés : Récidive de l’incontinence urinaire d’effort, Repositionnement de la bandelette, Incontinence urinaire d’effort, Bandelette sous-urétrale

Keywords : Recurrent stress urinary incontinence, Mesh readjustment, Stress urinary incontinence, Suburethral slings


Plan


 Niveau de preuve : 5.


© 2012  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 22 - N° 16

P. 1033-1038 - décembre 2012 Retour au numéro
Article précédent Article précédent
  • Facteurs pronostiques d’urétéro-hydronéphrose (UHN) chez les patients atteints de sclérose en plaques (SEP)
  • L. Viart, V. Elalouf, J. Petit, A. Al Khedr, P. Kristkowiak, F. Saint
| Article suivant Article suivant
  • Un cas de cryptochidie associée à un îlot surrénalien ectopique du cordon spermatique chez un homme de 51 ans
  • T. Sakuma, C. Maurin, D. Shimizu, S. Shinohara

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.