Résumé

Objective

To investigate the hemostatic capability of mono- and bipolar transurethral resection of the prostate by comparing the perioperative blood loss with the coagulation depth achieved with mono- and bipolar transurethral resection of the prostate.

Methods

A total of 136 patients with lower urinary tract symptoms associated with benign prostatic hyperplasia were randomized to undergo transurethral resection of the prostate using either a monopolar system (Karl Storz, Co., Tuttlingen, Germany) or a gyrus PlasmaKinetic bipolar system (Gyrus-ACMI Corporation, Maple Grove, MN). The operative time, resected tissue weight, decline in serum sodium and hemoglobin, postoperative bleeding, and the coagulation depth were compared.

Results

There were no statistically significant differences in operative time, resected tissue weight, and capsular perforation. The decline in hemoglobin and serum sodium was 1.15 ± 0.53 g/dL and 4.57 ± 0.71 mmol/L in monopolar transurethral resection of the prostate group, respectively, whereas they fell only 0.71 ± 0.42 g/dL and 2.02 ± 0.53 mmol/L in the bipolar transurethral resection of the prostate group, respectively (P <.001). The rate of postoperative bleeding was significantly higher in the monopolar transurethral resection of the prostate group (P = .027). The coagulation depths with mono- and bipolar transurethral resection of the prostate were 127.56 ± 27.76 and 148.48 ± 31.64 μm, respectively (P <.001).

Conclusion

Our results demonstrate that bipolar transurethral resection of the prostate causes less intraoperative hemoglobin drop and postoperative bleeding than monopolar transurethral resection of the prostate, which may be associated with the deeper coagulation depth of bipolar transurethral resection of the prostate.

Le texte complet de cet article est disponible en PDF.

Plan


 Financial Disclosure: The authors declare that they have no relevant financial interests.


© 2012  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 80 - N° 5

P. 1116-1120 - novembre 2012 Retour au numéro
Article précédent Article précédent
  • Maximum Isometric Detrusor Pressure to Measure Bladder Strength in Men With Postprostatectomy Incontinence
  • Christopher S. Elliott, Craig V. Comiter
| Article suivant Article suivant
  • Timing of Orchiopexy in the United States: A Quality-of-Care Indicator
  • Jenny H. Yiee, Christopher S. Saigal, Julie Lai, Hillary L. Copp, Bernard M. Churchill, Mark S. Litwin, Urologic Diseases in America Project a b

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.