S'abonner

Impact of access site selection and operator expertise on radiation exposure; a controlled prospective study - 15/10/12

Doi : 10.1016/j.ahj.2012.06.011 
Ted S. Lo, MBChB, MRCP, Karim Ratib, MBChB, Aun-Yeong Chong, MD, Gurbir Bhatia, MD, Mark Gunning, MD, James Nolan, MD
 Department of Cardiology, University Hospital of North Staffordshire, Stoke-on-Trent, United Kingdom 

Reprint requests: James Nolan, MD, Department of Cardiology, University Hospital of North Staffordshire, Newcastle Road Stoke-on-Trent ST4 6QG, United Kingdom.

Résumé

Background

Published data relating to arterial access site selection and radiation exposure during coronary procedures suggest radial access may lead to increased radiation exposure, but this is based on poorly controlled studies. We sought to measure radiation exposure to patients and operators during elective coronary angiography (CA) according to access site, with other procedure related variables controlled for. We also investigated the specific effect of operator expertise in relation to radiation exposure.

Methods

100 consecutive patients undergoing first time elective CA were recruited prospectively. An expert transradial (TR) and an expert transfemoral (TF) operator performed 25 cases each via their default route. A trainee cardiologist with intermediate experience in both access sites performed 25 cases via each route. Angiographic projections were standardised and optimised radiation protection was utilised for all procedures. The primary endpoints were operator and patient exposure, quantified by effective dose (ED) and dose area product (DAP) respectively. Secondary endpoints included fluoroscopy time (FT) and time to patient ambulation.

Results

The trainee operator recorded higher values for radiation exposure in radial and femoral cases when compared to the expert operators. There were no significant differences in radiation exposure during CA to operator or patient according to access site when standardised by operator experience. For the trainee, ED for TR and TF procedures was 8.8 ± 4.3 μSv and 8.5 ± 6.5 μSv (P = .86) and DAP was 25.4 ± 4.8 Gycm2 vs 25.2 ± 8.3 Gycm2 (P = .9). For the expert TR and TF operators, ED was 6.4 ± 4.7 μSv vs 6.1 ± 5.6 μSv (P = .85) and DAP was 21.7 ± 6.5 Gycm2 vs 22.4 ± 8.0 Gycm2, (P = .74). There was no significant difference in FT in relation to access site. Time to ambulation was significantly longer with TF access.

Conclusion

The use of TR access has no adverse effect on radiation exposure or FT for diagnostic CA, but does allow for quicker ambulation compared to TF access. The magnitude of radiation exposure is related to operator expertise for both access sites. The results of previous studies reflect the effect of uncontrolled patient and operator variables and not access site selection.

Le texte complet de cet article est disponible en PDF.

Plan


© 2012  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 164 - N° 4

P. 455-461 - octobre 2012 Retour au numéro
Article précédent Article précédent
  • Silent cerebral infarcts after cardiac catheterization: A randomized comparison of radial and femoral approaches
  • Martial Hamon, Janusz Lipiecki, Didier Carrié, Francesco Burzotta, Nicolas Durel, Guillaume Coutance, Nicolas Boudou, Cesare Colosimo, Carlo Trani, Nicolas Dumonteil, Rémy Morello, Fausto Viader, Béatrice Claise, Michèle Hamon
| Article suivant Article suivant
  • Transulnar approach as an alternative access site for coronary invasive procedures after transradial approach failure
  • Pedro Beraldo de Andrade, Marden André Tebet, Ederlon Ferreira Nogueira, Vinícius Cardozo Esteves, Mônica Vieira Athanazio de Andrade, André Labrunie, Luiz Alberto Piva e Mattos

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.