Validation des gazométries au cordon ombilical : étude au sein d’une maternité française - 03/10/12

Doi : 10.1016/j.gyobfe.2012.05.001 
D. Ernst a, , J. Clerc a, E. Decullier b, c, d, G. Gavanier e, O. Dupuis a
a Service de gynécologie-obstétrique, centre hospitalo-universitaire de Lyon-Sud, hospices civils de Lyon, 165, chemin du Grand-Revoyet, 69310 Pierre-Bénite, France 
b Pôle information médicale évaluation recherche, centre hospitalo-universitaire de Lyon-Sud, hospices civils de Lyon, 69003 Lyon, France 
c EA 4129 santé individu société, RECIF, université de Lyon, 69002 Lyon, France 
d Université Lyon-1, 69008 Lyon, France 
e École polytechnique, département de mécanique, 91128 Palaiseau cedex, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 3
Vidéos 0
Autres 0

Résumé

Objectif

En salle de naissance, l’évaluation de l’état de santé néonatale est primordiale. La réalisation et l’interprétation des gazométries au cordon de façon systématique permet une telle évaluation. Nous avons voulu établir la faisabilité et la fiabilité des gazométries au sein d’une maternité de type 2B.

Patientes et méthodes

Nous avons étudié rétrospectivement les gazométries au cordon de 1000 accouchements consécutifs, de façon systématique. Premièrement, nous avons établi leur faisabilité, définie par le rapport de gazométries complètes sur le nombre d’accouchements d’enfants nés vivants. Deuxièmement, nous avons établi leur fiabilité, définie par le rapport des gazométries qui remplissaient les critères de qualité initialement définis par Westgate et al., et revus par Kro et al., sur le nombre de gazométries complètes d’enfants nés vivants. Enfin, nous avons cherché des facteurs influençant ces résultats.

Résultats

La faisabilité des prélèvements au cordon systématiquement réalisés était de 91,6 % et la fiabilité de 80,7 %. Concernant le mode d’accouchement, 38,6 % des césariennes en urgence (IC 95 % [30,8–46,3] ; p<0,0001) aboutissaient à des gazométries non valides, alors que seulement 11,3 % des césariennes prophylactiques (IC 95 % [4,3–18,2] ; p<0,0001) donnaient lieu à des gazométries non valides. Faisabilité et fiabilité étaient donc significativement plus faibles lors des césariennes en urgence.

Discussion et conclusion

La réalisation d’une gazométrie systématique s’accompagnait de 8,4 % de gazométries incomplètes, et 19,3 % de gazométries ininterprétables. Une formation rigoureuse serait donc souhaitable pour améliorer la faisabilité et la fiabilité, notamment lors des césariennes en urgence.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward.

Patients and methods

Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results.

Results

The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8–46.3]; P<0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3–18.2]; P<0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians.

Discussion and conclusion

Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians.

Le texte complet de cet article est disponible en PDF.

Mots clés : Sang cordon ombilical, Gazométries, Fiabilité, Faisabilité, Critères de qualité, pH au cordon, Validation

Keywords : Umbilical cord blood, Gas analysis, Feasibility, Reliability, Quality criteria, Cord pH, Validation


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 40 - N° 10

P. 566-571 - octobre 2012 Retour au numéro
Article précédent Article précédent
  • Traitement de l’hypertrophie des petites lèvres. Évaluation de la nymphoplastie de réduction par résection longitudinale
  • M. Cayrac, R. Rouzier
| Article suivant Article suivant
  • Colpohystérectomie élargie par voie cœlioscopique dans les cancers du col utérin : étude de qualité de vie. À propos de 22 cas
  • E. Barranger, F. Isnard, A. Bricou, E. Darai, Y. Delpech

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.