Summary

Background

Patient self-assessment of postoperative knee flexion following knee replacement was introduced at our institution. This protocol had a dual objective: improve follow-up and act as an early indicator to identify patients at risk of requiring a manipulation under anaesthesia. The aim of our study was to audit the use of this patient self-assessment tool and evaluate whether these outcomes were being achieved.

Materials and methods

A prospective audit of patients admitted for total knee replacements under the care of one orthopaedic consultant between April and October 2009. Participants were asked to measure and record daily maximum knee flexion whilst sitting, from discharge through to six-week follow-up. Patients were advised to contact the arthroplasty team if flexion reduced by 10° or more for three consecutive days. Patient’s documented knee flexion was compared to that measured on discharge and at six weeks postoperatively by clinicians.

Results

Seventy-nine participants (82 knees) were included with 61 participants (64 knees) returning data for analysis (78% compliance rate). Comparison of patient and clinician measurements showed a mean difference of +2° with limits of agreements from −12° to +15°. At a mean follow-up of six weeks maximum flexion (measured by clinician) was 99° (95%CI 97°, 102°) and 92% had a 90°flexion or greater. During the audit period, six patients met the criteria to contact the arthroplasty team, however none of them followed this instruction.

Discussion

Patient self-assessment of knee flexion at home with a simple goniometer was accurate enough to be useful and 92% of patients reached 90° maximum flexion at six weeks. However this self-assessment method was not successful as an early indicator to identify patients at risk of requiring a manipulation under anaesthesia. Future studies into alternative identifiers are required.

Level of evidence

Level III. Investigating a diagnostic test.

Le texte complet de cet article est disponible en PDF.

Keywords : Total knee arthroplasty, Clinical audit, Knee flexion, Patient self-assessment, Risk identification tool, Manipulation under anaesthesia, Arthrofibrosis


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 6

P. 672-676 - octobre 2012 Retour au numéro
Article précédent Article précédent
  • Operative treatment of clavicle midshaft fractures using a locking compression plate: Comparison between mini-invasive plate osteosynthesis (MIPPO) technique and conventional open reduction
  • H. Jiang, W. Qu
| Article suivant Article suivant
  • Axial rotation of the first metatarsal head in a normal population and hallux valgus patients
  • J.-P. Mortier, J.-L. Bernard, M. Maestro

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.