S'abonner

Évaluation du positionnement de la bandelette rétro-urétrale transobturatrice par IRM pelvienne statique et dynamique - 24/08/12

Doi : 10.1016/j.purol.2012.03.001 
G. Papin a, , V. Tissot b, H. Le Penndu c, M. Nonent b, G. Fournier a
a Service de chirurgie urologique, hôpital de la Cavale-Blanche, CHRU de Brest, boulevard Tanguy-Prigent, 29200 Brest, France 
b Service de radiologie, hôpital de la Cavale-Blanche, CHRU de Brest, boulevard Tanguy-Prigent, 29200 Brest, France 
c Centre de radiologie Brest-Liberté, 1bis, place de la Liberté, 29200 Brest, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 5
Vidéos 0
Autres 0

Résumé

But

Évaluer l’intérêt de l’IRM pour définir les rapports anatomiques et fonctionnels entre la bandelette rétro-urétrale (BRU) Advance® et l’urètre sphinctérien, après mise en place chez des patients ayant une incontinence urinaire post-prostatectomie radicale.

Patients

Chez 12 patients traités pour incontinence urinaire post-prostatectomie, une IRM pelvienne statique et dynamique a été réalisée entre un et trois mois postopératoires. Pour huit patients, une IRM avait été effectuée en préopératoire permettant de la comparer aux séquences postopératoires. Les séquences statiques ont étudié les rapports anatomiques entre la bandelette et l’urètre sphinctérien, ainsi que l’impact sur la position de l’anastomose vésico-urétrale. Les séquences à la toux ont recherché l’existence d’une mobilité de l’urètre sphinctérien. Enfin, les séquences mictionnelles ont étudié l’impact de la bandelette sur l’urètre lors de la miction.

Résultats

La position de la bandelette était toujours visualisable, à une distance médiane de 5mm en arrière de la lumière urétrale. Les bras de la bandelette exerçaient une traction sous forme d’un V ouvert dont l’angle en coupe transversale entre un bras et la ligne intertubérosité ischiatique variait de 28 à 59°. En comparant les clichés pré- et postopératoires, la position de l’anastomose vésico-urétrale n’était pas modifiée. Sur les séquences préopératoires à la toux, quatre patients avaient une mobilité urétrale qui n’existait plus en postopératoire. Enfin, les sept patients ayant fait des clichés mictionnels avaient une miction sans sténose urétrale.

Conclusion

L’IRM était un examen intéressant pour mettre en évidence le positionnement de la bandelette par rapport à l’urètre sphinctérien. Correctement positionnée, la bandelette était rétro-urétrale et aucune sténose urétrale n’était visible lors de la miction.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose

To evaluate the usefulness of MRI to assess the anatomical and functional relationships between the transobturator male sling Advance® and the uretral sphincter, in patients treated for postprostatectomy urinary incontinence.

Patients

For 12 patients treated for postprostatectomy urinary incontinence using the transobturator male sling Advance®, a pelvic real-time MRI was performed between 1 and 3 months postoperatively. A comparison between pre- and postoperative MRI was performed in eight patients. The static sequences studied the anatomical relationships between the sling and the uretral sphincter, as well as the impact on the location of the vesico-uretral anastomosis. The dynamic sequences by coughing looked for the existence of an uretral sphincter mobility. Finally, the voiding sequences studied the impact of the sling on the uretral lumen during the micturition.

Results

The position of the sling was always visible, located at a median distance of 5mm from the posterior wall of the uretra. On transverse sections, the angles between the transobturator arms and the horizontal line between the ischial tuberosities varied from 28 to 59 degrees. The vesico-uretral anastomosis location was not modificated between pre and postoperative MRI. On the preop sequences by coughing, four patients had uretral mobility, which didn’t exist on postop sequences. To finish, the seven patients who were able to void during MRI, had micturition without uretral stenosis.

Conclusion

Pelvic MRI was a useful tool to assess the positioning of the sling and the relationships with the uretral sphincter. When correctly positioned, the sling was retro-uretrally and no urethral stenosis was visible during the micturition.

Le texte complet de cet article est disponible en PDF.

Mots clés : Incontinence urinaire, Bandelette transobturatrice, IRM, Prostatectomie radicale

Keywords : Urinary incontinence, Transobturator male sling, MRI, Radical prostatectomy


Plan


 Niveau de preuve : 5.


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 22 - N° 10

P. 602-609 - septembre 2012 Retour au numéro
Article précédent Article précédent
  • Bilharziose urinaire : une série française
  • A. Abdou, M. Tligui, G. Le Loup, G. Raynal
| Article suivant Article suivant
  • L’acétate de goséréline pourrait-il induire des hépatites d’allure auto-immune ?
  • C. Duburque, J.-L. Bonnal, P. Gosset, D. Lucidarme

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.