S'abonner

Comparison of bacterial contamination of blood conservation system and stopcock system arterial sampling lines used in critically ill patients - 31/07/12

Doi : 10.1016/j.ajic.2011.08.006 
Jun Oto, MD a, , Emiko Nakataki, MD a, Michiko Hata b, Yumiko Tsunano, MD a, Nao Okuda, MD a, Hideaki Imanaka, MD a, Masaji Nishimura, MD a
a Emergency and Critical Care Medicine, The University of Tokushima Graduate School, Tokushima, Japan 
b Microbiological Center, The University of Tokushima Graduate School, Tokushima, Japan 

Address correspondence to Jun Oto, MD, Department of Emergency and Critical Care Medicine, Tokushima University Hospital, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.

Abstract

Background

Commonly placed to monitor blood pressure and to aspirate blood, arterial lines frequently cause complications. The blood conservation system (BCS) forms a closed infusion line and may be expected to reduce complications caused by intraluminal contamination. We compared microbial contamination resulting from use of BCS and 3-way stopcock catheterization.

Methods

Patients who required arterial catheterization for at least 24 hours in our intensive care unit were randomly assigned to receive an arterial pressure monitoring system either with the BCS (test group) or with a 3-way stopcock (comparator group). To evaluate arterial line contamination, we qualitatively assessed the contamination of the catheter tip and intraluminal fluid.

Results

We analyzed microbial contamination for a total of 216 arterial catheters: 109 in the test group and 107 in the comparator group. We found no difference in the incidence of catheter tip colonization in the 2 groups (test group, 8/109 vs comparator group, 11/107; P = .48). There was a statistically significant correlation between catheter tip colonization and duration of arterial line utilization. We found statistically significantly lower intraluminal fluid contamination in the test group (test group, 2/109 vs comparator group, 9/107; P = .03). There was no relationship between intraluminal fluid contamination and catheter tip contamination.

Conclusion

There was less microbial contamination of intraluminal fluid when BCS was used for arterial catheterization.

Le texte complet de cet article est disponible en PDF.

Key Words : Arterial line contamination, Arterial blood conservation system, Arterial catheter-related blood stream infection


Plan


 Supported by departmental funding.
 Conflicts of interests: None to report.


Crown Copyright © 2012  Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 40 - N° 6

P. 530-534 - août 2012 Retour au numéro
Article précédent Article précédent
  • Prospective audit for antimicrobial stewardship in intensive care: Impact on resistance and clinical outcomes
  • Carlos A. DiazGranados
| Article suivant Article suivant
  • Contact precautions for methicillin-resistant Staphylococcus aureus colonization: Costly and unnecessary?
  • Michael R. Spence, Tereal Dammel, Shari Courser

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.