Reproducibility and influence of hand rotation on computer-aided joint space analysis - 30/06/12

Doi : 10.1016/j.jbspin.2011.07.011 
Alexander Pfeil a, , Andreas Hansch b, Julia Sommerfeld b, Rosemarie Fröber c, Diane M. Renz d, Gabriele Lehmann a, Ansgar Malich e, Gunter Wolf a, Joachim Böttcher f
a Department of Internal Medicine III, Friedrich-Schiller-University Jena, Erlanger Allee 101, 07747 Jena, Germany 
b Institute of Diagnostic and Interventional Radiology, Friedrich-Schiller-University Jena, Erlanger Allee 101, 07747 Jena, Germany 
c Institute of Anatomy I, Friedrich-Schiller-University Jena, Löbdergraben, Teichgraben 7, 07740 Jena, Germany 
d Department of Radiology, Charité University Medicine Berlin, Campus Virchow Clinic, Augustenburger Platz 1, 13353 Berlin, Germany 
e Department of Radiology, Suedharz Clinic Nordhausen, Dr Robert-Koch Street 39, 99734 Nordhausen, Germany 
f Institute of Diagnostic and Interventional Radiology, SRH Wald-Klinikum Gera, Straße des Friedens 122, 07548 Gera, Germany 

Corresponding author. Tel.: +49 3641 9324384; fax: +49-3641-9324302.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 2
Vidéos 0
Autres 0

Abstract

Objectives

Computer-aided joint space analysis (CAJSA) is a recently developed, semi-automated tool to aid in the measurement of joint space margins based on hand radiographs. The objective of this study is to verify the potential effect of hand rotation during X-ray imaging on the measurement of joint space width using CAJSA and to evaluate the reproducibility of the CAJSA technique in healthy subjects and in patients with rheumatoid arthritis.

Methods

All joint space distance (JSD) measurements were performed using CAJSA-technology at the metacarpophalangeal articulation based on conventional and digital hand radiographs.

Results

I. Hand rotation showed an effect on the reproducibility with CV ranging between 0.39% (angulation 1°) and 1.66% (angulation 19°). II. Regarding the overall reproducibility of the CAJSA method, the intra-radiograph reproducibility of JSD was calculated with CV=0.54% for conventional images and CV=0.38% for digital images. The inter-radiograph reproducibility error was observed with CV=0.66% (conventional images) and CV=0.63% (digital images). III. The study revealed a reproducibility for CAJSA measurements in RA ranging between 0.37% (JSD-MCP ring finger; van der Heijde-modification of the Sharp method Score 1) to 1.37% (JSD-MCP index finger; van der Heijde-modification of the Sharp method Score 3).

Conclusion

CAJSA measures JSD at the metacarpophalangeal articulation with high reproducibility in healthy subjects and in patients with differing stages of rheumatoid arthritis. Additional findings show that hand rotation during X-ray imaging has an impact on the CAJSA measurements; thus avoiding acquisition of hand radiographs with a rotation error of more than 15 degrees can be recommended.

Le texte complet de cet article est disponible en PDF.

Keywords : Rheumatoid arthritis, Computer-aided diagnosis, Computer-aided joint space analysis, Joint space width, X-ray imaging, Reproducibility


Plan


© 2011  Société française de rhumatologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 79 - N° 4

P. 384-388 - juillet 2012 Retour au numéro
Article précédent Article précédent
  • Assessment of hand trabecular bone texture with high resolution direct digital radiograph in rheumatoid arthritis: A case control study
  • Anne Fouque-Aubert, Stéphanie Boutroy, Hubert Marotte, Nicolas Vilayphiou, Eric Lespessailles, Claude-Laurent Benhamou, Pierre Miossec, Roland Chapurlat
| Article suivant Article suivant
  • Monitoring of bone turnover markers does not improve persistence with ibandronate treatment
  • Christian Roux, Bruno Giraudeau, Stéphanie Rouanet, Geneviève Dubourg, Elodie Perrodeau, Philippe Ravaud

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.