S'abonner

Thulium Laser Versus Holmium Laser Transurethral Enucleation of the Prostate: 18-Month Follow-up Data of a Single Center - 01/04/12

Doi : 10.1016/j.urology.2011.12.018 
Fengbo Zhang a, Qiang Shao a, , Thomas R.W. Herrmann b, Ye Tian a, Yuhai Zhang a
a Department of Urology, Beijing Friendship Hospital, Capital Medical University, Beijing, China 
b Division of Endourology and Minimal Invasive Therapy, Department of Urology, Urological Oncology, Hannover Medical School, Hannover, Germany 

Reprint requests: Qiang Shao, M.D., Department of Urology, Beijing Friendship Hospital, Capital Medical University, 95# Yong'An Road, Xicheng District, Beijing 100050 China

Résumé

Objective

To compare the clinical outcomes between thulium laser transurethral enucleation of the prostate (ThuLEP) (70 W) and holmium laser transurethral enucleation of the prostate (HoLEP) (90 W) in a prospective randomized trial with 18 months of follow-up. Both ThuLEP and HoLEP effectively relieve the obstructive symptoms due to benign prostatic hyperplasia (BPH).

Methods

A total of 133 consecutive patients with BPH were randomized to either ThuLEP (n = 71) or HoLEP (n = 62). An energy setting of 70 W and 90 W was used for the thulium and holmium laser in the enucleation procedure, respectively. The mushroom technique was used to fragment the enucleated lobes with the resection loop. The preoperative and postoperative parameters were compared.

Results

ThuLEP required a longer operation time (72.4 vs 61.5 minutes, P = .034) but resulted in less blood loss than HoLEP (130.0 vs 166.6 mL, P = .045). The catheterization time was comparable. At 18 months, the lower urinary tract symptom indexes were improved significantly in both groups compared with the baseline values. The International Prostate Symptom Score decreased to 5.2 in the ThuLEP group and 6.2 in the HoLEP group. The quality of life score and peak urinary flow rate were similar between the 2 groups (1.3 vs 1.2 and 23.4 vs 24.2 mL/s) and the postvoid residual urine volume decreased by 82.50% and 81.73% in the ThuLEP and HoLEP groups, respectively. The mean prostate-specific antigen decrease after HoLEP and ThuLEP was 30.43% and 43.36%, respectively. No urethral or bladder neck stricture were found in either group.

Conclusion

Both ThuLEP (70 W) and HoLEP (90 W) relieve lower urinary tract symptoms equally with high efficacy and safety. ThuLEP was statistically superior to HoLEP in blood loss and inferior to HoLEP in operation time, although the differences were clinically negligible. The mushroom technique could be adequate, without an additional mechanical tissue morcellator.

Le texte complet de cet article est disponible en PDF.

Plan


© 2012  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 79 - N° 4

P. 869-874 - avril 2012 Retour au numéro
Article précédent Article précédent
  • High-Grade Prostatic Adenocarcinoma Present in a Single Biopsy Core is Associated With Increased Extraprostatic Extension, Seminal Vesicle Invasion, and Positive Surgical Margins at Prostatectomy
  • Alcides Chaux, Daniel A. Fajardo, Nilda Gonzalez-Roibon, Alan W. Partin, Mario Eisenberger, Theodore L. DeWeese, George J. Netto
| Article suivant Article suivant
  • Hemodynamic Effects of Once-daily Tadalafil in Men With Signs and Symptoms of Benign Prostatic Hyperplasia on Concomitant ⍺1-Adrenergic Antagonist Therapy: Results of a Multicenter Randomized, Double-Blind, Placebo-controlled Trial
  • Evan Goldfischer, John J. Kowalczyk, William R. Clark, Erin Brady, Michael Anne Shane, Nancy Dgetluck, Suzanne R. Klise

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.