Comparaison en tomographie en cohérence optique (OCT Visante®) de la prédictibilité de la profondeur d’implantation des anneaux intracornéens après tunnélisation mécanique versus tunnélisation assistée au laser femtoseconde - 15/02/12

Doi : 10.1016/j.jfo.2011.03.014 
F.-X. Kouassi a, , b , C. Buestel a, B. Raman c, D. Melinte a, D. Touboul a, A. Gallois a, J. Colin a
a Service d’ophtalmologie, CHU Pellegrin, place Amélie-Rabat-Léon, 33000 Bordeaux, France 
b Service d’ophtalmologie, CHU, boulevard de l’université de Cocody, BP v 13, Abidjan, Côte d’Ivoire 
c Iris Advanced Eye Centre, CMC Hospital, Chandigarh, Inde 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Objectif

Cette étude avait pour objectif de comparer, en OCT Visante®, la prédictibilité de la profondeur d’implantation des anneaux intracornéens après tunnélisation manuelle versus tunnélisation au laser femtoseconde.

Patients et méthodes

Il s’agit d’une étude prospective observationnelle qui a inclus, après consentement éclairé des patients, 76 yeux kératocôniques dont 31 (groupe 1) ont bénéficié d’une implantation d’anneaux après tunnélisation manuelle et 45 (groupe 2) après tunnélisation au laser femtoseconde. La profondeur cible des anneaux était les deux tiers de l’épaisseur cornéenne périphérique entre 5 et 7mm de diamètre. Chaque patient a bénéficié d’une pachymétrie cornéenne (OCT Visante®) préopératoire et, à un mois postopératoire, de deux mesures de la profondeur des anneaux. L’une au niveau de l’anneau, l’autre sur la tangente à 700μm du bord interne et médian de l’anneau.

Résultats

Quel que soit le site de la mesure, la profondeur cible de 66 % de l’épaisseur cornéenne n’a été atteinte dans aucun groupe. La moyenne des différences entre la profondeur cible et celle mesurée était de 76,64±48,76μm dans le groupe 1et de 85,85±33,02μm dans le groupe 2. Ces différences n’étaient pas significatives. L’implantation a été plus superficielle en mesure tangentielle à 54,93±6,03 %, par rapport à 55,14±8,08 % au site de l’implant, dans le groupe 1 et à 56,17±5,82 % et 58,88 %±6,06 % respectivement dans le groupe 2.

Conclusion

Les anneaux ont été implantés moins profondément que prévu, quel que soit le mode de tunnélisation, manuel ou au laser femtoseconde. Les différences de profondeur entre les groupes n’étaient pas significatives.

Le texte complet de cet article est disponible en PDF.

Summary

Comparison of the depth predictability of intracorneal ring segment implantation by mechanical versus femtosecond laser-assisted techniques using optical coherence tomography (OCT Visante®).

Purpose

To compare the depth predictability of intracorneal ring segment implantation by mechanical versus femtosecond laser-assisted techniques using OCT Visante®.

Methods

This observational prospective study included, after patients’ consent, 76 keratoconic eyes, of which 31 eyes (group 1) were operated using the mechanical technique and 45 eyes (group 2) with the femtosecond laser-assisted technique. The target depth was two-thirds of the peripheral corneal thickness, ranging from 5 to 7mm in diameter. Every patient underwent high-resolution anterior segment OCT (OCT Visante®) measurement preoperatively and for the implant depth, 1month postoperatively. Then two different sites were used to determine the segment depth, at the segment site and tangentially, at a distance of 700μm central to the segment’s inner edge.

Results

Both measurement techniques demonstrated that targeted implantation depth of 66% of the corneal thickness was not observed in either group. The mean difference between the preoperative expected depth and final segment implantation was 76.64±48.76μm in the manual technique and 85.85±33.02μm in the femtosecond-assisted technique, with no statistically significant difference between the groups. Comparison between the measurement sites showed implantation depth to be shallower, 54.93±6.03%, at the tangential site compared to 55.14±8.08% at the implant site in group 1 and 56.17±5.82% versus 58.88±6.06%, respectively, in group 2.

Conclusion

Both mechanical and femtosecond laser-assisted techniques showed a more superficial Intacs® placement than predicted. No statistically significant difference was observed in implantation depth between the two groups.

Le texte complet de cet article est disponible en PDF.

Mots clés : Cornée, Kératocône, Intacs®, Laser femtoseconde, OCT-Visante®

Keywords : Cornea, Keratoconus, Intacs®, Femtosecond laser, OCT-Visante®


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 35 - N° 2

P. 94-99 - février 2012 Retour au numéro
Article précédent Article précédent
  • Étude de la cicatrice cutanée de la dacryocystorhinostomie par voie faciale
  • M.M. Mjarkesh, X. Morel, G. Renard
| Article suivant Article suivant
  • Thérapeutique du glaucome primitif à angle ouvert à Cotonou : à propos de 224 cas
  • I. Sounouvou, S. Tchabi, S. Monteiro, L. Yehouessi, C. Doutetien, S.K. Bassabi

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.