Interobserver and Intraobserver Variability in pH-Impedance Analysis between 10 Experts and Automated Analysis - 12/02/12

Doi : 10.1016/j.jpeds.2011.08.017 
Clara M. Loots, MSc 1, , Michiel P. van Wijk, MD, PhD 1, Kathleen Blondeau, PhD 2, Kasper Dalby, MD, PhD 3, Laura Peeters, MSc 1, Rachel Rosen, MD, PhD 4, Silvia Salvatore, MD 5, Tobias G. Wenzl, MD, PhD 6, Yvan Vandenplas, MD 7, Marc A. Benninga, MD 1, Taher I. Omari, PhD 8
1 Department of Pediatric Gastroenterology and Nutrition, Emma Kinderziekenhuis, Academic Medical Centre, Amsterdam, The Netherlands 
2 Translational Research Center for Gastrointestinal Disorders, University of Leuven, Leuven, Belgium 
3 H.C. Andersen Children's Hospital, Odensee, Denmark 
4 Children's Hospital Boston, Boston, MA 
5 Università dell'Insubria, Varese, Italy 
6 Klinik für Kinder- und Jugendmedizin, Universitätsklinikum der RWTH Aachen, Aachen, Germany 
7 Universitair Ziekenhuis Brussel, Brussels, Belgium 
8 Women's and Children's Hospital, University of Adelaide, Adelaide, South Australia, Australia 

Reprint requests: Clara M. Loots, Academisch Medisch Centrum, Kinder Motiliteitscentrum, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.

Abstract

Objective

To determine interobserver and intraobserver variability in pH-impedance interpretation between experts and accuracy of automated analysis (AA).

Study design

Ten pediatric 24-hour pH-impedance tracings were analyzed by 10 observers from 7 world groups and with AA. Detection of gastroesophageal reflux (GER) episodes was compared between observers and AA. Intraobserver agreement was assessed in 3 observers after 3 to 5 months.

Results

Overall, 1242 liquid and mixed GER events were detected, 490 (42%) were scored by the majority of observers, yielding moderate agreement (Cohen’s kappa [κ] = 0.46). Intraclass co-efficient for numbers of GER per study was 0.84 (P < .001). AA has 94% sensitivity rate and 74% specificity rate compared with majority consensus (≥6 observers). Agreement for gas GER was poor (κ = 0.11). Intraobserver agreement was κ = 0.49, κ = 0.71, and κ = 0.85 in 3 observers.

Conclusion

Interobserver agreement in combined pH-multichannel intraluminal impedance analysis in experts is moderate; only 42% of GER episodes were detected by the majority of observers. Detection of total GER numbers is more consistent. Considering these poor outcomes, AA seems favorable compared with manual analysis because of its reproducibility. However, the lower specificity rate suggests the need for refinement of AA before widespread use can be advocated.

Le texte complet de cet article est disponible en PDF.

Mots-clés : AA, GER, κ, MMS, MII, pH-MII


Plan


 The authors declare no conflicts of interest.


© 2012  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 160 - N° 3

P. 441 - mars 2012 Retour au numéro
Article précédent Article précédent
  • Reliability of Resting Blood Pressure Measurement and Classification Using an Oscillometric Device in Children with Chronic Kidney Disease
  • Joseph T. Flynn, Christopher B. Pierce, Edgar R. Miller, Jeanne Charleston, Joshua A. Samuels, Juan Kupferman, Susan L. Furth, Bradley A. Warady, Chronic Kidney Disease in Children Study Group ∗
| Article suivant Article suivant
  • Prevalence and Risk Factors for Feeding and Swallowing Difficulties in Spinal Muscular Atrophy Types II and III
  • Yen-Shan Chen, Hsiang-Hung Shih, Tai-Heng Chen, Chang-Hung Kuo, Yuh-Jyh Jong

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.