S'abonner

Improving the timeframe between blood collection and interferon gamma release assay using T-Cell Xtend® - 15/01/12

Doi : 10.1016/j.jinf.2011.10.017 
J.J.M. Bouwman a, , S.F.T. Thijsen a, A.W. Bossink b
a Department of Medical Microbiology and Immunology, Diakonessen Hospital Utrecht, The Netherlands 
b Department of Pulmonology, Diakonessen Hospital, Utrecht, The Netherlands 

Corresponding author. Department of Medical Microbiology and Immunology, Diakonessen Hospital Utrecht, Bosboomstraat 1, 3582 KE Utrecht, The Netherlands. Tel.: +31 88 250 6075; fax: +31 88 250 6695.

Summary

Vacutainer CPT tubes require blood samples for TSPOT.TB to be processed within 8 h. In this study we evaluated the ability of T-Cell Xtend to maintain the number and function of lymphocytes after 24 and 48 h of blood storage, giving similar test results as in freshly isolated specimens.

Methods

Whole blood specimens from 59 individuals were collected in Vacutainer CPT tubes (CPT) and lithium heparin (LH) tubes. CPT tubes were processed within 8 h. T-Cell Xtend was added to LH tubes after 24 or 48 h. We also left LH tubes untreated for 48 h. Total number of white blood cells (WBC) and proportions of lymphocytes and granulocytes were determined in the isolated Peripheral Blood Mononuclear Cells (PBMC). We also evaluated the performance of T-Cell Xtend in the TSPOT.TB assay.

Results

PBMC yields from T-Cell Xtend treated LH samples did not differ from PBMC yields from CPT tubes, but T-Cell Xtend had a pronounced effect on the proportions of lymphocytes and granulocytes. The mean lymphocyte percentage in PBMCs isolated from fresh CPT blood was 84.31 ± 1.14% (at t = 48 h), but was decreased to 52.72 ± 3.34% (p < 0.05) in untreated LH blood (at t = 48 h). This effect was neutralized by T-Cell Xtend (85.44 ± 0.74%). We observed a similar but opposite effect on granulocytes: The mean proportion in untreated LH blood was increased to 40.9 ± 3.67% (p < 0.001) compared to CPT blood (8.26 ± 0.89%). Treatment of LH samples with T-Cell Xtend (48 h) restored the proportion of granulocytes to 8.47 ± 0.61%. Enumeration of spots in the TSPOT.TB assay demonstrated good agreement between CPT and T-Cell Xtend results, even after 48 h.

Conclusions

T-Cell Xtend efficiently removes granulocytes from PBMC suspensions and increases the proportion of lymphocytes. TSPOT.TB results from T-Cell Xtend treated blood samples are at least comparable to the results obtained from the current CPT method. Use of standard lithium heparin blood combined with T-Cell Xtend allows up to 48 h storage of blood samples for batched processing and may further decrease the rate of indeterminate TSPOT.TB results.

Le texte complet de cet article est disponible en PDF.

Keywords : T-Cell Xtend®, TSPOT.TB®, Lithium heparin, IGRA, Interferon gamma, Tuberculosis

Abbreviations : PBMC, CPT, LH, LTBI, IGRA, MTB, PPD, ESAT-6, CFP10, ELISA, ELISPOT, IFN-γ, PHA, PMN, SFC, TST, WBC


Plan


© 2011  The British Infection Association. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 64 - N° 2

P. 197-203 - février 2012 Retour au numéro
Article précédent Article précédent
  • Questionable role of interferon-γ assays for smear-negative pulmonary TB in immunocompromised patients
  • Ji Ye Jung, Ju Eun Lim, Hye-jeong Lee, Young Mi Kim, Sang-Nae Cho, Se Kyu Kim, Joon Chang, Young Ae Kang
| Article suivant Article suivant
  • Hepatic safety of efavirenz in HIV/hepatitis C virus-coinfected patients with advanced liver fibrosis
  • Juan A. Pineda, Karin Neukam, Josep Mallolas, Luis F. López-Cortés, José A. Cartón, Pere Domingo, Santiago Moreno, José A. Iribarren, Bonaventura Clotet, Manuel Crespo, Ignacio de Los Santos, Enrique Ortega, Hernando Knobel, María J. Jiménez-Expósito, Juan Macías

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.