S'abonner

Diagnostic accuracy of a point-of-care troponin I assay for acute myocardial infarction within 3 hours after presentation in early presenters to the emergency department with chest pain - 14/12/11

Doi : 10.1016/j.ahj.2011.09.028 
Deborah B. Diercks a, h, , l , W. Frank Peacock b, h, l, Judd E. Hollander c, h, l, Adam J. Singer d, h, l, Robert Birkhahn e, h, l, Nathan Shapiro f, h, l, Ted Glynn g, h, l, Richard Nowack i, h, l, Basmah Safdar i, h, l, Chadwick D. Miller j, h, l, Elizabeth Lewandrowski k, h, l, John T. Nagurney k, h, l
a University of California, Davis, Sacramento, CA 
b The Cleveland Clinic, Cleveland, OH 
c University of Pennsylvania, Philadelphia, PA 
d Stony Brook University and Medical Center, Stony Brook, NY 
e New York Methodist Hospital, Brooklyn, NY 
f Beth Israel Deaconess Medical Center, Boston, MA 
g Ingham Regional Medical Center, Lansing, MT 
h Henry Ford Medical Center, Detroit, MI 
i Yale University, New Haven, CT 
j Wake Forest University Health Sciences, Winston-Salem, NC 
k Massachusetts General Hospital, Boston, MA 

Reprint requests: Deborah B. Diercks, MD, MSC, UCMDC, 2315 Stockton Blvd, PSSB 2100, Sacramento, CA 95817.

Résumé

Background

Guidelines recommend that serial cardiac marker testing to rule out acute myocardial infarction (AMI) be performed for 8 to 12 hours after symptom onset. We aim to determine the diagnostic accuracy of a contemporary point-of-care (POC) troponin I (TnI) assay within 3 hours for patients presenting within 8 hours of symptom onset.

Methods

The MIDAS study collected blood from patients presenting with suspected acute coronary syndrome at presentation and at 90 minutes, 3 hours, and 6 hours in whom the emergency physician planned an objective cardiac ischemia evaluation. Criterion standard diagnoses were adjudicated by experienced clinicians using all available medical records per American Heart Association/American College of Cardiology criteria. Reviewers were blinded to the investigational marker, Cardio3 TnI POC. The Cardio3 TnI reference value was defined as >0.05 ng/mL. Measures of diagnostic accuracy are presented with 95% CI.

Results

A total of 858 of 1107 patients met the inclusion criteria. The study cohort had 476 men (55.5%) with median age of 57.0 years (interquartile range 48.0-67.0 years). Median time from symptom onset to initial blood draw was 3.9 hours (interquartile range 2.7-5.2 hours). Acute myocardial infarction was diagnosed in 82 patients (9.6%). The sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio over 3 hours were 84.1, 93.4, 12.8, and 0.17, respectively. There was no significant improvement in diagnostic accuracy associated with adding 6-hour serial testing to the 3-hour sample.

Conclusion

In suspected patients with acute coronary syndrome presenting to the emergency department within 8 hours of symptom onset, 3 hours of serial testing with the Cardio3 TnI POC platform provides similar diagnostic accuracy for AMI as longer periods.

Le texte complet de cet article est disponible en PDF.

Plan


© 2012  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 163 - N° 1

P. 74 - janvier 2012 Retour au numéro
Article précédent Article précédent
  • Bridging the gender gap: Insights from a contemporary analysis of sex-related differences in the treatment and outcomes of patients with acute coronary syndromes
  • Stephanie Poon, Shaun G. Goodman, Raymond T. Yan, Raffaele Bugiardini, Arlene S. Bierman, Kim A. Eagle, Nina Johnston, Thao Huynh, Francois R. Grondin, Karin Schenck-Gustafsson, Andrew T. Yan
| Article suivant Article suivant
  • Long-term effects of smoking and smoking cessation on exercise stress testing: Three-year outcomes from a randomized clinical trial
  • Asha Asthana, Megan E. Piper, Patrick E. McBride, Ann Ward, Michael C. Fiore, Timothy B. Baker, James H. Stein

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.