S'abonner

Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: Prospective evaluation of bone union, precision and maintenance of correction in 51 cases - 26/10/11

Doi : 10.1016/j.otsr.2011.06.011 
T. Brosset a, G. Pasquier b, , c , H. Migaud b, c, F. Gougeon d
a Saint-Roch Surgical Center, route de Gordes, 84300 Cavaillon, France 
b C and D Orthopaedics Units, Roger-Salengro Hospital, Lille Teaching Hospital Regional Medical Center, rue Émile-Laine, 59037 Lille cedex, France 
c Lille North of France University, 59000 Lille, France 
d La Louvière Private Surgical Center, 122, rue de la Louvière, 59000 Lille, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

A medial opening wedge high tibial osteotomy (HTO), where the osteotomy site is filled, is often preferred to a lateral closing osteotomy, but filling the defect can lead to certain complications.

Hypothesis

A medial opening HTO can be performed without filling the bone defect if fixation is carried out with a specially-designed stiff locking plate.

Patients and methods

Fifty-one patients, 37 to 72 years of age where followed prospectively and continuously from 2003 to 2006. A single surgical technique was used: medial opening HTO with locked plate fixation (TomoFix™, Synthes) but without filling the defect. The preoperative genu varum could not exceed 15°. The following were evaluated: time to return to weight-bearing, IKS functional score, long-leg standing film performed preoperative, postoperative and at follow-up to evaluate limb alignment and validate the precision of the correction and its stability over time. A measurement of the area of bone union in the osteotomy site was used to quantify the rate of union.

Results

Bone union occurred at 4.5 months on average; two cases of incomplete union (7%) were found and revised with an autograft at 7 and 9 months. Lower-limb alignment was 7.5° of varus on average before surgery (3° to 15° varus, SD=2.85) and 1.2° of valgus on average after the surgery (4° varus to 5° valgus, SD=1.78). The correction was maintained at 1 year post-surgery. The average IKS knee score went from 69±15.5 (range 25 to 96) before surgery to 90±7.4 (range 66 to 98) at follow-up (P=0.0001). Full weight-bearing without assistance was possible after 3 months on average (range 1.5 to 8, SD=1.21). Forty-seven patients (92%) were fully weight-bearing after 2 months. Forty-eight patients were able to return to work and sporting activities at the same or a higher level than before the procedure.

Discussion

Bone union seems to happen more slowly when the defect is filled; however, there are doubts about radiological evaluation of bone union in different published studies. When osteotomy defect was left unfilled in this study, union and filling of 4/5 of the osteotomy site was obtained in 4.2 months for 49 of the 51 cases. Fixation with the locking plate is reliable and provides stable correction and the option for early weight-bearing.

Level of proof

Level IV, prospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : High tibial osteotomy, Medial opening, Knee, Knee osteoarthritis, Bone union, Locking plate


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 7

P. 705-711 - novembre 2011 Retour au numéro
Article précédent Article précédent
  • Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation
  • J. Berhouet, P. Beaufils, P. Boisrenoult, D. Frasca, N. Pujol
| Article suivant Article suivant
  • The concordance of MRI and arthroscopy in traumatic meniscal lesions in children
  • Y. Bouju, E. Carpentier, F. Bergerault, B. De Courtivron, C. Bonnard, P. Garaud

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.