S'abonner

Scapular notching in reverse shoulder arthroplasties: The influence of glenometaphyseal angle - 24/09/11

Doi : 10.1016/j.otsr.2011.06.007 
V. Falaise a, C. Levigne b, L. Favard a,

SOFEC

a Orthopaedic service 1, CHU Trousseau, university F.-Rabelais, 2 bis, boulevard Tonnellé, 37000 Tours, France 
b Orthopaedic surgery, clinique du Parc, 69000 Lyon, France 

Corresponding author. Tel.: +33 2 47 47 59 05.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Solutions described to limit the risk of scapular notching mainly concern the glenoid. Our hypothesis is that this risk also depends upon the glenoid-humeral relationship when the arm is resting along the body.

Patient and methods

This is a retrospective study of a continuous series of 85 reverse shoulder arthroplasties; 62 of these fulfilled inclusion criteria. The following parameters were studied: body mass index (BMI), inferior overhang of the glenosphere, the angles showing the position of the glenoid (GH) and the humerus (MH) in the scapular plane as well as the glenometaphyseal angle (GM=MH−GH), during an initial postoperative follow-up, at 1 and 2years, and at a final follow up of a mean 45months (24–81). The parameters studied were compared in two groups with and without scapular notching.

Results

There were 21 instances of notching at the final follow-up. This rate was significantly correlated to the BMI, which was a mean 27.2 in patients without a notch and 22.6 in patients with a notch, while the preoperative inclination of the glenoid in these groups was respectively 92.3° versus 85° respectively, the inferior overhang of the glenosphere was 4mm versus 2.8mm, the GM angle was 36° versus 47°, the MH angle at one year of follow-up was 135° versus 145° and the GH angle at the final follow-up was 103° versus 94° respectively. The BMI was significantly correlated to the GM angle, and a low BMI was associated with high values of this angle.

Discussion

The relative position of the glenoid and humeral components, as shown by the GM angle, was an essential factor in the development of a scapular notching. The humeral component of the GM angle evolved in thin patients with progressive adduction of the arm, which is associated with a risk of notching. This should be taken into account when performing reverse shoulder arthroplasties.

Level of evidence

Level IV retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Shoulder, Arthroplasty, Scapula, Reverse arthroplasty


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 6S

P. S131-S137 - octobre 2011 Retour au numéro
Article précédent Article précédent
  • Arthroscopic treatment of rotator cuff tear in the over-60s: Repair is preferable to isolated acromioplasty-tenotomy in the short term
  • C. Dezaly, F. Sirveaux, R. Philippe, F. Wein-Remy, J. Sedaghatian, O. Roche, D. Molé

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.