Abstract

It is occasionally difficult to record the standard 12-lead electrocardiograph (ECG) in emergency patients. The aim of this study was to evaluate the influence on electrocardiographic wave form recordings of moving the location of electrodes from the standard limb lead position to the trunk. The participants were 10 normal subjects and 20 patients with heart disease. In the new lead system, the limb electrodes were placed on the anterior acromial region and the anterior superior iliac spine using adhesive electrodes. Conventional 12-lead ECGs were recorded by the standard and the new lead system simultaneously in the supine position. Wave form analysis was done by an automatic analysis program. Motion artifacts in the recordings were less in the new lead system. The R wave amplitude of the new lead system increased in leads II, III and aVF, and decreased in leads I and aVL. However, the amplitudes of each wave obtained by standard electrocardiography and the new lead system correlated well (y = 1.008x + 2.038, r = 0.99, n = 2,880). In 99.6% of all wave forms, the differences in amplitudes were within 5% of the values of standard recordings. The average of differences in the ST-segment was 2.6 ± 11.4 μV. The frontal plane QRS axis obtained by the new lead system showed a vertical shift of 7.8 ± 8.5 degrees (y = 0.94911x + 10.346, r = 0.98, n = 30). The recording errors produced by the new lead system were within the permissible range of variation. The new lead system is a reasonable alternative for recording ECGs if application of the standard lead is difficult in an emergency.

Le texte complet de cet article est disponible en PDF.

Keywords : ECG, lead system, prehospital care, emergency



© 1995  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 5

P. 514-517 - septembre 1995 Retour au numéro
Article précédent Article précédent
  • Are spinal precautions necessary in all seizure patients?
  • C.L McArthur, Christopher T Rooke
| Article suivant Article suivant
  • Emergency care for posttonsillectomy and postadenoidectomy hemorrhage
  • Kirsten G Steketee, Earl J Reisdorff

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.