S'abonner

PATIENT–VENTILATOR INTERACTIONS - 11/09/11

Doi : 10.1016/S0272-5231(05)70325-7 
Cameron R. Dick, MD, Catherine S.H. Sassoon, MD
a Section of Pulmonary and Critical Care Medicine, University of California, Irvine, College of Medicine, Irvine (CRD, CSHS); and Veterans Administration Medical Center, Long Beach (CSHS), California 

Résumé

The primary goals of mechanical ventilation are to restore adequate gas exchange, unload the over-tasked respiratory muscles, and prevent ventilator-related complications while allowing the underlying disease process to resolve. Clinicians have become attuned to the management of abnormal blood gases and the complications associated with mechanical ventilation. Bedside assessment of the degree of ventilator unloading has been limited, however, by the inability to make a convenient estimation of the patient's work of breathing or breathing effort. Breathing effort can be defined as the product of pressure generated by the contracting respiratory muscles and the duration of contraction, quantified as the pressure–time product (PTP).20 The degree of ventilator unloading and the load imposed by the ventilator are determinants of patient–ventilator interaction during acute respiratory failure and discontinuation from mechanical ventilation. Despite the appearance of patient–ventilator synchrony, estimation of PTP actually may reveal considerable patient effort.29 In cases of extreme discordance, these interactions commonly are described as “fighting the ventilator.”

When the patient is completely passive, without patient-initiated breaths, the ventilator assumes the entire workload. With patient-triggered breaths, however, the degree of ventilatory unloading by the machine depends on the matching between the ventilator-delivered gas flow and the patient's ventilatory demand—i.e., patient–ventilator synchrony. Ideally, the ventilator shouldadjust flow delivery instantaneously in response to the patient's changing respiratory drive and workload. Although proportional-assist ventilation would appear to meet the aforementioned requirement,9799 unfortunately, proportional-assist ventilation is not available commercially.

Failure to achieve patient–ventilator synchrony may result in impaired gas exchange, with hypoxemia and hypercapnia; increased load to the respiratory muscles; and increased intrathoracic pressure, compromising cardiovascular function.88 Factors inherent to the patient and the ventilator determine patient–ventilator interaction.

Patient-related factors
 Respiratory center output
 Respiratory system mechanics
 Dynamic hyperinflation/intrinsic positive,   end-expiratory pressure
Ventilator-related factors
 Ventilator triggering
 Flow delivery
 Tidal volume
 Inspiratory pressure
 Apparatus resistance

In this review, the authors focus on the determinants of patient–ventilator interactions and the strategies to improve the interaction in terms of its effect on the work of breathing or breathing effort.

Le texte complet de cet article est disponible en PDF.

Plan


 Address reprint requests to Catherine S. H. Sassoon, MD, Section of Pulmonary and Critical Care Medicine, VA Medical Center (111P), 5901 East Seventh Street, Long Beach, CA 90822
All material in this article is in the public domain with the exception of any borrowed tables and figures.


© 1996  W. B. Saunders Company. Publié par Elsevier Masson SAS. Tous droits réservés.© 1993  © 1994  © 1995  © 1995  © 1995 
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 17 - N° 3

P. 423-438 - septembre 1996 Retour au numéro
Article précédent Article précédent
  • NEW MODES OF MECHANICAL VENTILATION
  • Neil R. MacIntyre
| Article suivant Article suivant
  • COMPLICATIONS OF MECHANICAL VENTILATION : A Bedside Approach
  • Robert L. Keith, David J. Pierson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.