S'abonner

Comparison of Left Ventricular Ejection Fraction in Congenital Heart Disease by Visual Versus Algorithmic Determination - 10/09/11

Doi : 10.1016/S0002-9149(97)00674-7 
Rufino Nascimento A, , Décio Pereira A, António Freitas A, Eva Pereira A, Isabel Mendonça A, Martim Dinis A
A Unidade de Cardiologia Pediátrica, Serviço de Cardiologia, Centro Hospitalar do Funchal, Funchal, Portugal. 

*Rufino Nascimento, MD, Unidade de Cardiologia Pediátrica, Hospital Cruz de Carvalho, 9000 Funchal, Portugal.

Abstract

Two-dimensional (2D) echocardiographic visual estimation of left ventricular (LV) ejection fraction (EF) in patients with acquired heart disease yields results that are comparable to those obtained by recommended algorithms. However, there is no information concerning its accuracy in congenital heart disease. This study compares applicability, accuracy, and reproducibility of LVEF by visual estimation with that by currently used algorithms (cylinder hemiellipsoid, ellipsoid biplane, and biplane method of disks) in 92 consecutive patients with congenital heart disease but unrepaired complete atrioventricular septal defect, univentricular heart, and hypoplastic left ventricle, using 3D echocardiography as the reference method. Visual estimation of LVEF could be applied in all cases. Because of technically inadequate 2D echocardiographic images for volume measurement, analysis for comparison could be performed in 71 patients (77%), aged 1 day to 47 years. The correlation between 3D echocardiographic and visual estimation was 0.91 (SEE 3.3%), cylinder hemiellipsoid, 0.86 (SEE 3.9%), ellipsoid biplane 0.87 (SEE 3.9%), and biplane method of disks 0.93 (SEE 3.2%). Intraobserver variability was similar for all 2D echo methods. Interobserver variability was greater for visual estimation. In conclusion, visual estimation of LVEF is applicable to most patients with congenital heart disease, yielding results that are comparable to those obtained by currently used 2D echocardiographic algorithms.

Le texte complet de cet article est disponible en PDF.

Plan


© 1997  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 80 - N° 10

P. 1331-1335 - novembre 1997 Retour au numéro
Article précédent Article précédent
  • Automated Assessment of Mitral Regurgitant Volume and Regurgitant Fraction by a Newly Developed Digital Color Doppler Velocity Profile Integration Method
  • Takeshi Hozumi, Kiyoshi Yoshida, Takashi Akasaka, Tsutomu Takagi, Atsushi Yamamuro, Toshikazu Yagi, Junichi Yoshikawa
| Article suivant Article suivant
  • In-Laboratory Removal of Femoral Sheath Following Protamine Administration in Patients Having Intracoronary Stent Implantation
  • Manuel Pan, José Suárez de Lezo, Alfonso Medina, Miguel Romero, Enrique Hernández, José Segura, Francisco Melian, Fernando Wangüemert, Manuel Landin, Fernando Ben??tez, Manuel Amat, Francisco Velasco, Antonio Torres

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.