S'abonner

Relation of contrast echo intensity and flow velocity to the amplification of contrast opacification produced by intermittent ultrasound transmission - 10/09/11

Doi : 10.1016/S0002-8703(97)70027-9 
Koji Ohmori, MD, Bruno Cotter, MD, Oi Ling Kwan, RDCS, Katsufumi Mizushige, MD, Anthony N. DeMaria, MD
San Diego and La Jolla, Calif. 

Abstract

Intermittent ultrasound transmission during contrast echocardiography, so-called transient response imaging (TRI), amplifies contrast intensity. This effect of TRI is attributed to decreased microbubble destruction by reduced exposure time to ultrasound energy. The present study examined the hypothesis that the signal amplification produced by TRI is related to the baseline intensity present in the image and the velocity of flow. We performed second harmonic (2.5/5.0 MHz) imaging during both continuous (frame rate 55 Hz) and electrocardiogram-triggered TRI mode. Contrast images produced by perfluorohexane microbubbles (AF0150) in a steady flow model were obtained every minute throughout the decay phase at transit velocities of 8.1, 6.2, 3.4, 1.9, and 0.7 cm/sec. The decay of videointensity over time could be fitted to a sigmoid curve for both imaging modes with r > 0.99 for individual velocities. The intensity with TRI was greater than that with continuous imaging (CI) at any time and velocity. The mean increase in intensity between modes throughout decay was 8.2 ± 3.7, 12.8 ± 4.2, 25.7 ± 5.8, 49.5 ± 8.0, and 64.0 ± 14.4 gray levels for the respective velocity levels studied (p < 0.0001). Although varying with baseline intensity at early and late phases, the TRI amplification plateaued during middecay, and within the intensity range of 16 to 143 gray levels for CI and 67 to 186 gray levels for TRI, it showed no overlap among the different velocity levels. Thus the ability of TRI to enhance contrast opacification is much greater at low flow velocities, which has implications regarding the mechanism of TRI effect and preferential visualization of intramyocardial coronary arteries by this agent. Although this effect was influenced by the baseline intensity, it was relatively constant for each velocity level within an optimal intensity range during middecay, providing the basis for flow velocity measurement by contrast echo. (Am Heart J 1997;134:1066-74.)

Le texte complet de cet article est disponible en PDF.

Plan


 From the Division of Cardiology, School of Medicine, University of California at San Diego, and VA Medical Center, La Jolla.
 Reprint requests: Anthony N. DeMaria, MD, Division of Cardiology, University of California at San Diego, UCSD Medical Center, 200 West Arbor Dr., San Diego, CA 92103-8411.
 4/1/84885


© 1997  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 134 - N° 6

P. 1066-1074 - décembre 1997 Retour au numéro
Article précédent Article précédent
  • Effect of dobutamine-induced myocardial ischemia on Doppler echocardiography after myocardial infarction
  • Chao-Hung Wang, Wen-Jin Cherng, Ming-Jui Hung
| Article suivant Article suivant
  • Failure of intravascular ultrasound to predict dissection after balloon angioplasty by using plaque characteristics
  • Aad van der Lugt, Elma J. Gussenhoven, Clemens von Birgelen, Jo-Ann Tai, Herman Pieterman

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.