Abstract

Background In the era of coronary stenting with high-pressure expansion, stent thrombosis remains a major life-threatening risk. Because of its superior imaging mode, intracoronary ultrasound could provide insight into potential risk factors for stent thrombosis.

Patients and Methods In 215 patients with stent implantations controlled by intracoronary ultrasound, four occurrences of subacute stent thrombosis, two complete acute thrombotic occlusions, and four occurrences of incomplete acute thrombosis were observed. All stents were expanded with inflation pressures of at least 14 atm (17 ± 3 atm). The clinical data and the qualitative and quantitative ultrasound information were compared between stents with thrombosis and stents without thrombosis. The luminal area and the plaque border of the reference segments, and of the smallest and largest site of the stented segment after the initial and final expansion, were measured.

Results Stents in the left anterior descending artery were more often involved in stent thrombosis than other vessels, but the vessel dimensions in this target vessel were smaller than in the right coronary artery. The plaque burden was considerably larger after stent implantation with subsequent thrombosis compared with no thrombosis (74.1 ± 8.8% vs 63.6 ± 8.0%; p < 0.001), and the stent area was smaller (4.80% ± 1.33 mm2 vs 6.86 ± 2.08 mm2; p < 0.01). In stents with thrombosis the plaque burden of the stent site with the smallest and largest lumen differed by 15.2%, whereas the difference in plaque burden in stents without thrombosis was 2.7%. Intracoronary ultrasound showed that the best risk predictor of thrombosis was the residual plaque burden of the stented segment (odds ratio 15.7 [confidence interval 2.4 to 104.7]), and a small stent area after implantation (odds ratio 6.8 [confidence interval 1.9 to 24.3]).

Conclusion In a multivariate risk analysis plaque burden was the strongest independent risk factor for stent thrombosis. The amount of residual plaque mass around the stent might be a potential trigger for thrombus formation. (Am Heart J 1998;135:300-9.)

Le texte complet de cet article est disponible en PDF.

Plan


 From the Department of Cardiology, Center for Internal Medicine, Georg-August-University Goettingen.
 Reprint requests: Gerald S. Werner, MD, Department of Cardiology, Georg-August-University, Robert-Koch-Str. 40, 37075 Goettingen, Germany. E-mail: gwerner1@gwdg.de
 4/1/86279


© 1998  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 135 - N° 2

P. 300-309 - février 1998 Retour au numéro
Article précédent Article précédent
  • Prehospital delay in patients with acute coronary heart disease: Concordance between patient interviews and medical records
  • Robert J. Goldberg, Paul G. McGovern, Thomas Guggina, Judith Savageau, Wayen D. Rosamond, Russell V. Luepker
| Article suivant Article suivant
  • Intercenter variability in outcome for patients treated with direct coronary angioplasty during acute myocardial infarction
  • Timothy F. Christian, James H. O'Keefe, Marcus A. DeWood, Michael G. Spain, Cindy L. Grines, Peter B. Berger, Raymond J. Gibbons

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.