S'abonner

Quantification of the aortic valve area in three-dimensional echocardiographic data sets: Analysis of orifice overestimation resulting from suboptimal cut-plane selection - 09/09/11

Doi : 10.1016/S0002-8703(98)70064-X 
Jaroslaw D. Kasprzak, MD, PhDa, Youssef F.M. Nosir, MD, Anita Dall'Agata, MD, Abdou Elhendy, MD, Meindert Taams, MD, PhD, Folkert J. Ten Cate, MD, PhD, Jos R.T.C. Roelandt, MD, PhD
Rotterdam, The Netherlands, and Lód'z, Poland 

Abstract

Background: Our study was designed to determine the feasibility of three-dimensional echocardiographic (3DE) aortic valve area planimetry and to evaluate potential errors resulting from suboptimal imaging plane position. Methods and Results: Transesophageal echocardiography with acquisition of images for 3DE was performed in 27 patients. Aortic valve orifice was planimetered in two-dimensional echocardiograms (2DE) and in two-dimensional views reconstructed from 3DE data sets optimized for the level of the cusp tips. To evaluate the errors caused by suboptimal cut-plane selection, orifice was also measured in cut-planes angulated by 10, 20, and 30 degrees or shifted by 1.5 to 7.5 mm. Planimetered orifice areas was similar in 2DE and 3DE studies: 2.09 ± 0.97 cm2 versus 2.07 ± 0.92 cm2. Significant overestimation was observed with cut-plane angulation (0.09, 0.19, and 0.34 cm2 at 10 degree increments) or parallel shift (0.11, 0.22, 0.33, 0.43, and 0.63 cm2 at 1.5 mm increments). Three-dimensional echocardiographic measurement reproducibility was very low and superior to that of 2DE. Conclusions: Three-dimensional echocardiography allows accurate aortic valve area quantification with excellent reproducibility. Relatively small inaccuracy in cut-plane adjustment is a major source of errors in aortic valve area planimetry. (Am Heart J 1998;135:995-1003.)

Le texte complet de cet article est disponible en PDF.

Plan


 From Thoraxcenter, Division of Cardiology, Erasmus University and University Hospital Rotterdam–Dijkzigt, and the aCardiology Department, Medical University of Lódź
 Reprints requests: Jaroslaw D. Kasprzak, Thoraxcenter, Ba 302, Erasmus University Rotterdam, PO Box 1738, 3000DR Rotterdam, The Netherlands.Copyright © 1998 by Mosby, Inc.
 4/1/88288


© 1998  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 135 - N° 6

P. 995-1003 - juin 1998 Retour au numéro
Article précédent Article précédent
  • Relation between single tomographic intravascular ultrasound image parameters and intracoronary Doppler flow velocity in patients with intermediately severe coronary stenoses
  • Jeffery W. Moses, Cenap Undermir, Janet E. Strain, Edward M. Kreps, Jill E. Higgins, Gilbert W. Gleim, Morton J. Kern
| Article suivant Article suivant
  • Heart rate variability during the first month of smoking cessation
  • Masayuki Yotsukura, Yasushi Koide, Keita Fujii, Yasuhide Tomono, Atsuo Katayama, Hiromi Ando, Jun Suzuki, Kyozo Ishikawa

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.