S'abonner

Urinary eosinophil-derived neurotoxin/protein X: A simple method for assessing eosinophil degranulation in vivo - 09/09/11

Doi : 10.1016/S0091-6749(98)70202-7 
Vincent Cottin, MDa, Philippe Deviller, MDb, Frédérique Tardy, MDb, Jean-François Cordier, MDa
Lyon, France 

Abstract

Background: Eosinophil-derived neurotoxin/protein X (EDN/EPX), one of the cationic granule proteins released by polymorphonuclear eosinophils, can be detected in human urine. Objective: We sought to evaluate whether the urinary release of EDN/EPX was dependent on the blood eosinophil cell count, the bronchoalveolar eosinophil cell count, or both and on the clinical diagnosis. We also attempted to determine the precise kinetics of decrease of EDN excretion and eosinophil counts after the onset of corticosteroid treatment. Methods: Daily urinary release of EDN/EPX was measured by radioimmunoassay in 28 patients with high hypereosinophilia (group 1), 32 patients with moderate hypereosinophilia (group 2), 26 patients without hypereosinophilia at the time of the study but with a known pulmonary disease involving eosinophils (group 3), and 13 control patients (group 4). Results: The urinary excretion of EDN/EPX was significantly higher in patients from groups 1 or 2 than in patients from groups 3 or 4. Particularly high levels of EDN/EPX excretion were observed in patients from groups 1 or 2 with chronic eosinophilic pneumonia (chronic eosinophilic pneumonia: 4.7 ± 8.1 mg/day, control subjects: 0.39 ± 0.33 mg/day, p < 0.001). Urinary excretion of EDN/EPX was significantly correlated with blood (r = 0.66, p < 0.001) and differential bronchoalveolar (r = 0.62, p = 0.04) eosinophil cell counts in patients from group 1 but not from the other groups. Corticosteroid treatment was followed by a significant decrease in EDN/EPX excretion. The kinetics of decrease in EDN/EPX were delayed as compared with the dramatic drop in peripheral eosinophil counts. Distinct kinetics between urinary EDN/EPX and eosinophil counts differentiated the recurrence of chronic eosinophilic pneumonia from an asthma attack in one patient. Conclusion: Measurement of urinary EDN/EPX excretion may be a useful indicator of eosinophil degranulation in vivo. (J Allergy Clin Immunol 1998;101:116-23.)

Le texte complet de cet article est disponible en PDF.

Keywords : eosinophil, degranulation, cationic protein, eosinophil-derived neurotoxin, chronic eosinophilic pneumonia

Abbreviations : ECP, EDN/EPX, EPO, MBP


Plan


 Supported by grant HCL-PNRC 005 from Ministère de la Santé et de l'Action Humanitaire, France.
 This work was preliminarily presented at the International Conference of the American Thoracic Society/American Lung Association, New Orleans, Louisiana, May 12-15, 1996.
 Reprint requests: Jean-François Cordier, MD, Service de Pneumologie, Hôpital Cardiovasculaire et Pneumologique Louis Pradel, 69394 Lyon Cedex 03, France.
 1/1/86352


© 1998  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 1

P. 116-123 - janvier 1998 Retour au numéro
Article précédent Article précédent
  • Comparison of inflammatory events in skin sites with and without cutaneous late-phase reactions after prominent immediate IgE-mediated responses
  • Burton Zweiman, Anne R. Moskovitz, Carolyn von Allmen
| Article suivant Article suivant
  • Measurement of cat allergen levels in the home by use of an amplified ELISA
  • Mary Elizabeth Bollinger, Robert A. Wood, Peihua Chen, Peyton A. Eggleston

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.