S'abonner

Temporal Variability of Vena Contracta and Jet Areas with Color Doppler in Aortic Regurgitation: A Chronic Animal Model Study - 09/09/11

Doi : 10.1016/S0894-7317(98)70158-0 
Masahiro Ishii, MD, Michael Jones, MD, Takahiro Shiota, MD, PhD, Izumi Yamada, MD, Brian Sinclair, MD, Russell S. Heinrich, BS, Ajit P. Yoganathan, PhD, David J. Sahn, MD
Portland Oregon; Bethesda Maryland; Atlanta Georgia 

Abstract

Objective. The purpose of our study was to determine the temporal variability of regurgitant color Doppler jet areas and the width of the color Doppler imaged vena contracta for evaluating the severity of aortic regurgitation. Methods. Twenty-nine hemodynamically different states were obtained pharmacologically in 8 sheep 20 weeks after surgery to produce aortic regurgitation. Aortic regurgitation was quantified by peak and mean regurgitant flow rates, regurgitant stroke volumes, and regurgitant fractions determined using pulmonary and aortic electromagnetic flow probes and meters balanced against each other. The regurgitant jet areas and the widths of color Doppler imaged vena contracta were measured at 4 different times during diastole to determine the temporal variability of this parameter. Results. When measured at 4 different temporal points in diastole, a significant change was observed in the size of the color Doppler imaged regurgitant jet (percent of difference: from 31.1% to 904%; 233% ± 245%). Simple linear regression analysis between each color jet area at 4 different periods in diastole and flow meter-based severity of the aortic regurgitation showed only weak correlation (0.23 < r < 0.49). In contrast, for most conditions only a slight change was observed in the width of the color Doppler imaged vena contracta during the diastolic regurgitant period (percent of difference, vena contracta: from 2.4% to 12.9%, 5.8% ± 3.2%). In addition, for each period the width of the color Doppler imaged vena contracta at the 4 different time periods in diastole correlated quite strongly with volumetric measures of the severity of aortic regurgitation (0.81 < r < 0.90) and with the instantaneous flow rate for the corresponding period (0.85 < r < 0.87). Conclusions. Color Doppler imaged vena contracta may provide a simple, practical, and accurate method for quantifying aortic regurgitation, even when using a single frame color Doppler flow mapping image. (J Am Soc Echocardiogr 1998;11:1064-71.)

Le texte complet de cet article est disponible en PDF.

Plan


 From Oregon Health Sciences University, Portland, Ore; the National Heart, Lung and Blood Institute, Bethesda, Md; and Georgia Institute of Technology, Atlanta, Ga.
 Supported in part by grant HL43287 from the National Heart, Lung and Blood Institute.
 Reprint requests: David J. Sahn, MD, The Clinical Care Center for Congenital Heart Disease, Oregon Health Sciences University, 3181 SW Sam Jackson Park Rd, UHN 60, Portland, OR 97201-3098.
 27/1/93358


© 1998  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 11 - N° 11

P. 1064-1071 - novembre 1998 Retour au numéro
Article précédent Article précédent
  • Application of Proximal Isovelocity Surface Area Method to Determine Prosthetic Mitral Valve Area
  • Muzaffer Degertekin, Murat Gençbay, Yelda Başaran, İbrahim Duran, Hüseyın Yilmaz, İsmet Dindar, Fikret Turan
| Article suivant Article suivant
  • Percutaneous Echocardiographically Guided Pericardiocentesis in Pediatric Patients: Evaluation of Safety and Efficacy
  • Teresa S.M. Tsang, Eyad K. El-Najdawi, James B. Seward, Donald J. Hagler, William K. Freeman, Patrick W. O’Leary

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.