Abstract

Background The asymmetry and complex shape of the right ventricle have made it difficult to determine right ventricular (RV) volume with 2-dimensional echocardiography. Three-dimensional cardiac imaging improves visualization of cardiac anatomy but is also complex and time consuming. A newly developed volumetric scanning system holds promise of obviating past limitations. Methods Real-time, transthoracic 3-dimensional echocardiographic images of the right ventricle were obtained with a high-speed volumetric ultrasound system that uses a 16:1 parallel processing schema from a 2.5 MHz matrix phased-array scanner to interrogate an entire pyramidal volume in real time. The instrumentation was used to measure RV volume in 8 excised canine hearts; dynamic real-time 3-dimensional images were also obtained from 14 normal subjects. Results Three-dimensional images were obtained in vitro and in vivo during intravenous hand-agitated saline injection to determine RV volumes. The RV volumes by real-time 3-dimensional echocardiography are well correlated with those of drained in vitro (y = 1.26x - 9.92, r = 0.97, P < .0001, standard error of the estimate = 3.26 mL). For human subjects, the end-diastolic and end-systolic RV volumes were calculated by tracing serial cross-sectional, inclined C scans; functional data were validated by comparing the scans with conventional 2-dimensional echocardiographic indexes of left ventricular stroke volume. Conclusions These data indicate that RV volume measurements of excised heart by real-time 3-dimensional echocardiography are accurate and that beat-to-beat RV quantitative measurement applying this imaging method is possible. The new application of real-time 3-dimensional echocardiography presents the opportunity to develop new descriptors of cardiac performance. (Am Heart J 1999;137:958-67.)

Le texte complet de cet article est disponible en PDF.

Plan


 Supported by a grant from the NSC/ERC for Emerging Cardiovascular Technologies, CDR-8622201.
☆☆ Reprint requests: Joseph Kisslo, MD, Box 3818, Duke University Medical Center, Durham, NC 27710.E-mail: joseph.kisslo@duke.edu
 0002-8703/99/$8.00 + 0   4/1/93842


© 1999  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 137 - N° 5

P. 958-966 - mai 1999 Retour au numéro
Article précédent Article précédent
  • Comparative ability of myocardial perfusion single-photon emission computed tomography to detect coronary artery disease in patients with and without diabetes mellitus
  • Xingping Kang, Daniel S. Berman, Howard Lewin, Romalisa Miranda, Jacob Erel, John D. Friedman, Aman M. Amanullah
| Article suivant Article suivant
  • Determinants of aortic artifacts during transesophageal echocardiography of the ascending aorta
  • Maria Angela Losi, Sandro Betocchi, Carlo Briguori, Fiore Manganelli, Quirino Ciampi, Leonardo Pace, Gabriele Iannelli, Nicola Spampinato, Massimo Chiariello

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.