S'abonner

Calcified plaque cross-sectional area in human arteries: Correlation between intravascular ultrasound and undecalcified histology - 08/09/11

Doi : 10.1016/S0002-8703(99)70496-5 
Heikki Kostamaa, BS, Janis Donovan, BA, Shunji Kasaoka, MD, Jonathan Tobis, MD, Lorraine Fitzpatrick, MD
Orange, Calif, and Rochester, Minn 
From the Division of Cardiology, University of California, Irvine, and the Division of Endocrinology and Metabolism, Department of Medicine, Mayo Clinic and Mayo Foundation 

Abstract

Background The purpose of this investigation was to quantify the amount of intralesional calcium detected by intravascular ultrasound (IVUS) compared with undecalcified histology in human arteries. This method preserves intralesional calcium and reduces sectioning artifacts, thereby providing an accurate measure of calcium plaque morphology. Methods and Results Ten arterial segments (5 coronary, 5 iliac) were obtained at autopsy. IVUS imaging was performed with a 4.9F catheter at an automated pullback rate of 1.0 mm/s. The undecalcified arteries were dehydrated in ascending alcohol and polymerized in glycol methylmethacrylate. The arteries were cut into 200-μm sections with an Isomet low-speed saw and stained with Goldner’s trichrome. The lumen cross-sectional area, the calcium plaque cross-sectional area, the calcium plaque depth, length, and angle of arc of calcified plaque were measured from the IVUS images and histologic sections. In 24 selected cross sections, there were 38 separate calcium plaques. An independent observer correctly identified 34 of 38 calcified plaques for a sensitivity of 89% and specificity of 97%. The total mean calcified plaque cross-sectional area measured from histology was 4.6 ± 4.1 mm2 compared with 2.8 ± 2.3 mm2 by IVUS (P = .002). Plaque depth measured by histology was 1.2 ± 0.4 mm versus 0.7 ± 0.2 mm by IVUS (P = .001). The length of calcium plaques measured by histology was 3.6 ± 1.78 mm versus 3.6 ± 1.5 mm for IVUS (r = 0.79). Conclusions IVUS accurately depicts circumferential calcified lesions with high sensitivity (89%) and specificity (97%). However, IVUS underestimates the total calcified plaque cross-sectional area by 39%. This is mainly because of the inability of the ultrasound to penetrate intralesional calcium, which leads to an underestimation of the depth of calcium by 45%. (Am Heart J 1999;137:482-8.)

Le texte complet de cet article est disponible en PDF.

Plan


 Reprint requests: Jonathan M. Tobis, MD, UCI Medical Center, Division of Cardiology, 101 The City Dr, Bldg 53, Room 100, Orange, CA 92868-3298.
 0002-8703/99/$8.00 + 0   4/1/91288


© 1999  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 137 - N° 3

P. 482-488 - mars 1999 Retour au numéro
Article précédent Article précédent
  • Angle dependence of intravascular ultrasound imaging and its feasibility in tissue characterization of human atherosclerotic tissue
  • Takafumi Hiro, Cyril Y. Leung, Houshang Karimi, Ali R. Farvid, Jonathan M. Tobis
| Article suivant Article suivant
  • Early low-dose dobutamine echocardiography predicts late functional recovery after thrombolyzed acute myocardial infarction
  • Bassem A. Samad, Mats Frick, Jonas Höjer, Mats Jensen Urstad

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.