S'abonner

Usefulness of subcutaneous low molecular weight heparin (ardeparin) for reduction of restenosis after percutaneous transluminal coronary angioplasty - 08/09/11

Doi : 10.1016/S0002-9149(99)00141-1 
Lawrence W. Gimple, MD a, , Howard C. Herrmann, MD b, Michael Winniford, MD c, Eberhard Mammen, MD d

for the Ardeparin and Restenosis Study Group

  See for participating centers and principal investigators.
, Appendix

a Cardiovascular Division, University of Virginia Health Science Center, Charlottesville, Virginia, USA 
b Department of Medicine, University of Pennsylvania Medical System, Philadelphia, Pennsylvania, USA 
c Cardiovascular Division, University of Iowa Hospitals, Iowa City, Iowa, USA 
d Wayne State University School of Medicine, Detroit, Michigan, USA 

*Address for reprints: Lawrence W. Gimple, MD, HSC Box 158-Cardiovascular Division, University of Virginia Health Sciences Center, Charlottesville, Virginia 22908

Abstract

In addition to its anticoagulant effects, heparin is known to have antiproliferative effects on vascular smooth muscle cells. Ardeparin is a partially depolymerized (low molecular weight) heparin that has a longer half-life than unfractionated heparin. Following successful coronary balloon angioplasty, 565 patients were randomized to treatment with twice-daily subcutaneous ardeparin 50 anti-Xa U/kg (low dose) or 100 anti Xa U/kg body weight (high dose), or placebo for 3 months. Follow-up angiography was performed in 415 patients at 4 months, or earlier if clinically indicated. Additionally, patients underwent treadmill exercise electrocardiography at 2 weeks and 4 months. This study was designed to test the hypothesis that 3 months of subcutaneous dosing of ardeparin would reduce angiographic restenosis after coronary balloon angioplasty. Ardeparin had no effect on the incidence of angiographic restenosis (prespecified definition: ≥50% luminal diameter narrowing plus a loss of 50% of initial gain or absolute decrease of 20% of luminal diameter). Neither the mean luminal diameters nor mean percent diameter stenoses were different among the treatment groups before, after, or 4 months after balloon angioplasty. On exercise electrocardiography at 2 weeks and 4 months, patients in all treatment groups had similar exercise tolerance, incidence of angina, and frequency of ST depression. Thus, ardeparin treatment given subcutaneously for 3 months after successful balloon angioplasty does not reduce either angiographic or clinical measures of restenosis.

Le texte complet de cet article est disponible en PDF.

Plan


 The Ardeparin and Restenosis Study was supported by Wyeth Ayerst Research, Radnor, Pennsylvania.


© 1999  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 83 - N° 11

P. 1524-1529 - juin 1999 Retour au numéro
Article précédent Article précédent
  • Intravascular ultrasound assessment of the relation between early and late changes in arterial area and neointimal hyperplasia after percutaneous transluminal coronary angioplasty and directional coronary atherectomy
  • Gary S Mintz, Takeshi Kimura, Masakiyo Nobuyoshi, Martin B Leon
| Article suivant Article suivant
  • Presence and significance of the left atrionodal connection during atrioventricular nodal reentrant tachycardia
  • Frédéric Anselme, Panos Papageorgiou, Kevin Monahan, Marco Zardini, Noel Boyle, Laurence M Epstein, Mark E Josephson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.