S'abonner

Measuring maximal percent area stenosis poststent placement with intracoronary Doppler and the continuity equation and correlation with intracoronary ultrasound and angiography - 08/09/11

Doi : 10.1016/S0002-9149(99)00410-5 
Jassim Al Suwaidi, MB a : ChB, Stuart T. Higano, MD a, David R. Holmes, MD a, Charanjit S. Rihal, MD a, Amir Lerman, MD a,
a Center for Coronary Physiology and Imaging, the Division of Cardiovascular Diseases and Department of Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota, USA 

*Address for reprints: Amir Lerman, MD, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905

Abstract

Quantitative coronary angiography (QCA) and intracoronary ultrasound (ICUS) are methods for anatomic assessment of stent deployment. Intracoronary Doppler is primarily a method for the physiologic assessment of coronary stenoses. It correlates well with traditional noninvasive measurements of lesion significance. Intracoronary Doppler was used for the anatomic assessment of de novo coronary artery stenosis with variable success; however, its use for anatomic assessment of adequate stent deployment is unavailable. A rapid, automated software program was developed based on a modified continuity equation to calculate the maximal in-stent percent area stenosis by comparing the maximal in-stent velocity to an average reference velocity (proximal and distal). This study was designed to compare the Doppler method of an anatomic assessment with QCA and ICUS in 15 patients. Physiologic success of stent deployment was determined by the distal coronary flow reserve to 24 to 36 μg of intracoronary adenosine. Following successful stent deployment, distal coronary flow reserve increased significantly from a baseline of 1.6 ± 0.5 to 2.9 ±1.1. There was a significant correlation between the maximal in-stent percent area stenosis as measured by Doppler and both QCA (r = 0.78, p <0.01) and ICUS (r = 0.84, p <0.01). This study demonstrates that maximal in-stent percent area stenosis can be measured by intracoronary Doppler and a novel software program. The intracoronary Doppler guidewire method can assess the adequacy of stent deployment using both anatomic and physiologic principles and may supplement other quantitative methodologies.

Le texte complet de cet article est disponible en PDF.

Plan


 This study was supported by the Miami Heart Research Institute, Miami, Florida; The Rappaport Vascular Biology Program; and the Mayo Foundation, Rochester, Minnesota.


© 1999  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 84 - N° 6

P. 650-654 - septembre 1999 Retour au numéro
Article précédent Article précédent
  • Short- and long-term outcomes of Wiktor stent implantation at low versus high pressures
  • Paul Yang, Mariann Gyongyosi, Ali Hassan, Günter Heyer, Werner Klein, Olev Luha, Edwin Maurer, Volker Mühlberger, Othmar Pachinger, Heinz Sochor, Josef Sykora, Heinrich Weber, Franz Weidinger, Dietmar Glogar, on behalf of the Austrian Wiktor Stent Study Group
| Article suivant Article suivant
  • Effect of simvastatin treatment on the electronegative low-density lipoprotein present in patients with heterozygous familial hypercholesterolemia
  • José L Sánchez-Quesada, Carles Otal-Entraigas, Miquel Franco, Oscar Jorba, Francesc González-Sastre, Francisco Blanco-Vaca, Jordi Ordóñez-Llanos

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.