Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction - 08/09/11

Doi : 10.1016/S0002-9610(99)00124-5 
Judy Petersen, RN a,  : MN, AOCN, Joseph H Delaney, MD b, Mark T Brakstad, MD c, Ronald K Rowbotham, MS d, Charles M Bagley, MD e
a Department of Oncology (JP), Northwest Cancer Center, Seattle, Washington, USA 
b Department of Radiology (JHD), Northwest Cancer Center, Seattle, Washington, USA 
c Department of Surgery (MTB), Northwest Cancer Center, Seattle, Washington, USA 
d Department of Research and Development (RKR), Northwest Hospital, Northwest Cancer Center, Seattle, Washington, USA 
e Medical Oncology (CMB), Northwest Cancer Center, Seattle, Washington, USA 

*Requests for reprints should be addressed to Judy Petersen, RN, MN, AOCN, Oncology Services, Northwest Hospital, 1550 N 115th Street, Seattle, Washington 98133

Abstract

Background: Silicone venous access devices (VADs) are commonly used for multiple intravenous infusions and blood sampling in chronically ill patients, particularly cancer patients. These devices are susceptible to malfunctions most commonly characterized by difficulty infusing fluids or withdrawing blood. We hypothesized that the incidence of such malfunctions is primarily related to the position of the catheter tip relative to the superior vena cava/right atrial junction.

Methods: We reviewed medical records for 141 patients in whom silicone venous access devices were used. Chest radiographs obtained following catheter insertion were reviewed by a single radiologist to rule out pneumothorax and determine the position of the catheter tip. Other potential factors included in the analysis were catheter brand, the vein into which the catheter was inserted, and the side (right or left). A malfunction was defined as resistance to flushing or infusion of a substance, complete inability to infuse a substance, resistance to blood aspiration attempts, or absence of blood return with aspiration, occurring any time during which the catheter was in place. Multiple logistic regression was used to determine which factor(s) most strongly predicted catheter malfunction.

Results: Catheter tip location was the only factor that was statistically predictive of malfunctions (coefficient 0.842, P < 0.001). A significant increase in malfunctions was observed in cases where the catheter tip was located greater than 4 cm superior to the junction of the right atrium and the superior vena cava (z-test of proportions, P = 0.003). Malfunctions were minimized in those cases where the catheter tip was located in the right atrium.

Conclusions: These results indicate that malfunctions can be minimized in silicone venous access catheters by locating the catheter tip as close to the superior vena cava/right atrial junction as possible, or slightly inside the right atrium. To ensure proper location of the catheter tip, placement should be performed under fluoroscopy, and a radiograph should be obtained immediately following placement, with the patient in the upright position.

Le texte complet de cet article est disponible en PDF.

Plan


© 1999  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 178 - N° 1

P. 38-41 - juillet 1999 Retour au numéro
Article précédent Article précédent
  • Preliminary prospective randomized experience with vascular clips in the creation of arteriovenous fistulae for hemodialysis
  • A.Frederick Schild, Jeff Raines
| Article suivant Article suivant
  • Is splenectomy for massive splenomegaly safe in children?
  • Ahmed H Al-Salem

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.