Abstract

Evaluating predictors of appropriate implantable cardioverter-defibrillator (ICD) therapy in patients with idiopathic dilated cardiomyopathy (IDC) may be helpful in developing risk stratification strategies for these patients. Fifty-four patients with IDC underwent ICD implantation and were followed up. Twenty-three patients (42%) had a class I indication for ICD implantation; the remaining patients underwent implantation for multiple risk factors for sudden death including left ventricular dysfunction, nonsustained ventricular tachycardia, syncope, or positive electrophysiologic study results. Clinical, electrocardiographic, and electrophysiologic data were collected. Appropriate ICD therapy was defined as an antitachycardia pacing therapy or shock for tachyarrhythmia determined to be either ventricular tachycardia or ventricular fibrillation. Appropriate ICD therapy was observed in 23 patients (42%). There was a significant difference in use of β-blocker therapy between patients who did and did not have appropriate ICD therapy (p <0.0003). Cox regression analysis identified the following univariate predictors (p <0.1): class I indication (p <0.005) and lack of use of β-blocker therapy (p <0.0007). In multivariate analysis, only lack of β-blocker use (relative risk 0.15, 95% confidence intervals 0.05 to 0.45; p <0.0007) was identified as a predictor of appropriate ICD therapy. Of the patients who received ICD therapy, only 4 (17%) were taking β blockers, whereas 21 of the 31 patients (68%) who did not receive ICD therapy were treated with β blockers (p <0.0003). In patients with IDC selected for ICD implantation, the most consistent predictor of appropriate ICD therapy was lack of β-blocker use. Attempts should be made to administer β blockers to these patients, if tolerated.

Le texte complet de cet article est disponible en PDF.

Plan


© 2002  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 89 - N° 9

P. 1072-1076 - mai 2002 Retour au numéro
Article précédent Article précédent
  • Usefulness of pulsed tissue Doppler imaging for evaluating systolic and diastolic left ventricular function in patients with AL (primary) amyloidosis
  • Jun Koyama, Patricia A Ray-Sequin, Ravin Davidoff, Rodney H Falk
| Article suivant Article suivant
  • Usefulness of magnetic resonance imaging dobutamine stress in asymptomatic and minimally symptomatic patients with decreased cardiac reserve from congenital heart disease (complete and corrected transposition of the great arteries and subpulmonic obstruction)
  • Igor I Tulevski, Ernst E van der Wall, Maarten Groenink, Ali Dodge-Khatami, Alexander Hirsch, Jaap Stoker, Barbara J.M Mulder

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.