S'abonner

Preoperative evaluation of hepatic lesions for the staging of hepatocellular and metastatic liver carcinoma using endoscopic ultrasonography - 01/09/11

Doi : 10.1016/S0002-9610(02)01092-9 
Samir S Awad, M.D. a, , Shawn Fagan, M.D. a, Suhaib Abudayyeh, M.D. b, Nagla Karim, M.D. b, David H Berger, M.D. a, Kamran Ayub, M.D. b
a Michael E. DeBakey Department of Surgery, Houston VAMC, Surgical Service (112), 2002 Holcombe Blvd., Houston, TX 77030, USA 
b Department of Medicine, Division of Gastroenterology, Baylor College of Medicine, Houston VAMC, Houston, TX, USA 

*Corresponding author. Tel.: +1-713-794-7139; fax: +1-713-794-7352.

Abstract

Background:

Noninvasive imaging techniques, such as dynamic computed tomography (CT), magnetic resonance imaging and transabdominal ultrasonography are limited in their ability to detect hepatic lesions less than one cm. Intraoperative ultrasonography (IOUS) is currently the most sensitive modality for the detection of small hepatic lesions. However, IOUS is invasive requiring laparoscopy or formal laparotomy. We sought to evaluate the feasibility of using endoscopic ultrasonograhpy (EUS) for the detection and diagnosis of hepatic masses in patients with hepatocellular cancer (HCCA) and metastatic lesions (ML). We hypothesized that EUS could detect small (<1.0 cm) hepatic lesions undetectable by CT scan and could be used for biopsy of deep-seated hepatic lesions.

Methods:

Consecutive patients referred for EUS with suspected liver lesions were evaluated between July 2000 and October 2001. All patients underwent EUS using an Olympus (EM30) radial echoendoscope. If liver lesions were confirmed and fine needle aspiration (FNA) was deemed necessary, a linear array scope was used and an FNA performed with a 22-gauge needle. Two passes were made for each lesion.

Results

14 patients underwent evaluation with dynamic CT scans and EUS. In all 14 patients, EUS successfully identified hepatic lesions ranging in size from 0.3 cm to 14 cm (right lobe: n = 3, left lobe: n = 1, bilobar: n = 8). Moreover, EUS identified new or additional lesions in 28% (4 of 14) of the patients, all less than 0.5 cm in size (HCCA: n = 2, ML: n = 2), influencing the clinical management. In 2 of 14 patients EUS identified liver lesions, previously described as suspicious by CT scan, to be hemangiomas. Nine patients underwent EUS-guided FNA of hepatic lesions (deep seated: n = 3, superficial: n = 6). All FNA passes yielded adequate specimens (malignant: n = 8, benign: n = 1).

Conclusions

Our preliminary experience suggests that EUS is a feasible preoperative staging tool for liver masses suspected to be HCCA or metastatic lesions. EUS can detect small hepatic lesions previously undetected by dynamic CT scans. Furthermore, EUS-guided FNA can confirm additional HCCA liver lesions or liver metastases, in deep-seated locations, upstaging patients and changing clinical management.

Le texte complet de cet article est disponible en PDF.

Keywords : Endoscopic ultrasonography, Hepatocellular cancer, Metastatic liver carcinoma, Fine needle aspiration, Staging


Plan


© 2002  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 184 - N° 6

P. 601-604 - décembre 2002 Retour au numéro
Article précédent Article précédent
  • Discussion
| Article suivant Article suivant
  • Discussion

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.