An alternative linear stapling technique for performing Roux-en-Y anastomosis - 01/09/11
Abstract |
Background: |
The use of stapling devices for performing gastrointestinal anastomosis has gained wide acceptance in the last decade. Linear cutting devices have been used routinely during gastrointestinal operations in our hospital since 1992. However, we still have shortage of stapling devices due to cost reduction politics.
Methods |
We propose a modification of the standard technique in order to reduce the number of devices used. Our technique employs a single stapled including the section of the jejunum and the side-to-side jejunoanastomosis.
Results |
We have used this technique for 1 year without complications related to the stapled anastomosis.
Conclusions |
This technique may reduce the time of reconstruction of Roux-en-Y anastomosis without interfering in its final result. This modified technique may be useful in hospitals with reduced economic resources.
Le texte complet de cet article est disponible en PDF.Keywords : Anastomosis, Roux-en-Y, Surgical stapling
Plan
Vol 184 - N° 5
P. 449-451 - novembre 2002 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?