S'abonner

Percutaneous management of thoracolumbar burst fractures: Evolution of techniques and strategy - 31/08/11

Doi : 10.1016/j.otsr.2011.03.020 
B. Blondel a, S. Fuentes b, , G. Pech-Gourg b, T. Adetchessi b, P. Tropiano a, H. Dufour b
a Orthopaedics department, Northern academic Hospital, Mediterranean University, Chemin des Bourrely, 13915 Marseille, France 
b Department of Neurosurgery, Timone Hospital, Mediterranean University, 249, rue Saint-Pierre, 13005 Marseille, France 

Corresponding author. Tel.: +33 49 13 85 543; fax: +33 49 14 92 518.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

A number of techniques have been described in the management of thoracolumbar spinal fractures, testimony to the absence of consensus on their treatment. For the past few years, minimally invasive techniques have been developed to limit surgery-related iatrogenic injury. The objective of this study was to report the results of percutaneous management of these lesions and the technical progress made based on our experience.

Patients and methods

Twenty-nine patients presenting an A3 fracture, with a mean age of 51 years, were included in this study. All had a balloon kyphoplasty and percutaneous osteosynthesis. Of the first 22 cases, kyphoplasty was the initial procedure performed associated with reduction maneuvers using distraction. Assessment was clinical (neurological status and pain intensity) and radiological (implant positioning, cement leakage, restoration of local kyphosis and any loss of correction).

Results

In the overall series, the mean local kyphosis correction was 11° with a 2° angle loss at the last follow-up. Pain assessment showed significant improvement, decreasing from 6/10 to 1/10 on discharge. The mean hospital stay lasted 4 days. On the follow-up radiological exams, no cases of extrapedicular screw migration were noted; in two cases, lateral cement leakage was found. The results were equivalent in terms of correction no matter which procedure was performed first, although for the second part of the series the technology was available to bend the spinal fixation rod to the desired curve.

Discussion

The results of this study support the growing interest in minimally invasive techniques in the management of spinal injuries with no neurological deficit. In addition, the evolving material makes it possible to come close to conventional techniques, including reduction maneuvers, while limiting muscle injury by using a purely percutaneous approach. Rigorous patient selection is necessary and the time to learn the procedure must be taken into account. Studies with a longer follow-up are required to confirm the stability of the correction over time.

Level of evidence

Level IV. Retrospective observational study.

Le texte complet de cet article est disponible en PDF.

Keywords : Thoracolumbar fractures, Percutaneous osteosynthesis, Minimally invasive, Kyphoplasty


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 5

P. 527-532 - septembre 2011 Retour au numéro
Article précédent Article précédent
  • Calcitonin use in giant cell bone tumors
  • H. Nouri, M. Hedi Meherzi, M. Ouertatani, M. Mestiri, K. Zehi, M. Douik, M. Zouari
| Article suivant Article suivant
  • Medicoeconomic evaluation of total disc replacement based on French National Health Care System data
  • N. Bronsard, S. Litrico, I. Hovorka, P. Paquis, B. Gastaud, G. Daideri, J.-J. Greffeuille, P. Boileau

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.