Effect of an implantable cardioverter defibrillator with atrial detection and shock therapies on patient-perceived, health-related quality of life - 28/08/11

Doi : 10.1016/S0002-8703(02)94817-9 
David M Newman, MD, FACC a, , Paul Dorian, MD a, Miney Paquette, MSc a, Neil Sulke, MD b, Michael R Gold, MD, PhD, FACC c, David S Schwartzman, MD, FACC d, Katie Schaaf, MS e, Kathy Wood, PhD e, Linda Johnson, PhD, e

Worldwide Jewel AF AF-Only Investigators

a Department of Medicine, St. Michael’s Hospital, University of Toronto, Toronto, Ontario, Canada 
b Eastborne Hospital, Eastborne, United Kingdom 
c Medical University of South Carolina, Charleston, SC, USA 
d University of Pittsburgh, Pittsburgh, Pa, USA 
e Medtronic, Minneapolis, Minn, USA 

*Reprint requests: David M. Newman, MD, FACC, St. Michael’s Hospital, 30 Bond St, Room 7-051Q, Toronto, Ontario, Canada, M5B 1W8.

Abstract

Background

This study used a device (DDD implantable cardioverter defibrillator [ICD]) capable of delivering pacing and shock therapies to restore normal sinus rhythm in patients with atrial tachycardias or atrial fibrillation (AF). The purpose of this study was to assess the effect of the device on patient-perceived, health-related quality of life (QOL).

Methods

The DDD ICD was implanted in 267 patients with drug refractory, symptomatic AF from 45 centers across Europe, the United States, and Canada. Patients completed self-reported, validated QOL assessments at baseline and at 3- and 6-month follow-up visits (The Medical Outcomes Short Form 36 [SF-36] and the Symptom Checklist [SCL]).

Results

The mean age of the study group was 62 ± 12 years, and 73% of the patients were male. A total of 150 patients completed SF-36 assessments, and 138 patients completed SCL assessments at all 3 times. Baseline scores were more impaired (P < .05) on most SF-36 scales compared with norms for a general population, but were similar to a comparison group of patients with AF who were referred to tertiary care centers. The role-physical, physical functioning, vitality, mental health, and social functioning scales all improved significantly with time (all P < .04). Similarly, symptom frequency and severity (SCL) also improved significantly from baseline to 6 months (both P < .01). Shock therapy was delivered in 86 of the 150 patients (57%) with complete SF-36 evaluations. There was no evidence that receiving shocks decreased the relative improvement in QOL associated with implantation of the device.

Conclusions

In a 6-month period, QOL improves after implantation of a DDD ICD with atrial shock and pacing therapies. These improvements were not attenuated by receipt of shocks.

Le texte complet de cet article est disponible en PDF.

Plan


 Supported in part by grants from Medtronic, Minneapolis, Minn.


© 2003  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 145 - N° 5

P. 841-846 - mai 2003 Retour au numéro
Article précédent Article précédent
  • Insulin sensitivity in young women with vasovagal syncope
  • Graciela Aurora Ruiz, Cecilia Calvar, Ricardo Hermes, Daniel Rivadeneira, Viviana Bengolea, Raul Chirife, Maria Cristina Tentori, Ricardo Jorge Gelpi
| Article suivant Article suivant
  • Comparison of acute changes in left ventricular volume, systolic and diastolic functions, and intraventricular synchronicity after biventricular and right ventricular pacing for heart failure
  • Cheuk-Man Yu, Hong Lin, Wing-Hong Fung, Qing Zhang, Shun-Ling Kong, John E Sanderson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.