S'abonner

An evaluation of the use of new doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model - 28/08/11

Doi : 10.1016/S0894-7317(03)00083-X 
Tomotsugu Tabata, MD, PhD a, Lisa A Cardon, RDCS a, Guy P Armstrong, MD a, Kiyotaka Fukamach, MD, PhD b, Masami Takagaki, MD b, Yoshie Ochiai, MD b, Patrick M McCarthy, MD c, James D Thomas, MD, FACC a,
a Cardiovascular Imaging Center, Department of Cardiology,The Cleveland Clinic Foundation, Cleveland, OhioUSA 
b Department of Biomedical Engineering, Lerner Research Institute (K.F., M.T., Y.O.),The Cleveland Clinic Foundation, Cleveland, OhioUSA 
c Department of Thoracic and Cardiovascular Surgery (P.M.M.), The Cleveland Clinic Foundation, Cleveland, Ohio, USA 

*Reprint requests: James D. Thomas, MD, FACC, Cardiovascular Imaging Center, Department of Cardiology/F15, The Cleveland Clinic Foundation, 9500 Euclid Ave, Cleveland, OH 44195, USA

Abstract

Background

Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited.

Purpose and methods

We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation.

Results

With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P < .0001). In contrast to the mitral inflow velocities, mitral annulus early diastolic velocity decreased steadily (12.3-7.3 cm/s) resulting in a dramatic decrease in mitral annulus early/late (1.22-0.57) diastolic velocity with no tendency toward pseudonormalization. The color M-mode Doppler flow propagation velocity also showed significant steady decrease (57-24 cm/s) throughout the pacing period. Multiple regression analysis chose mitral annulus systolic velocity (r = 0.895, P < .0001) and propagation velocity (r = 0.782, P < .0001) for the most important factor predicting LV systolic and diastolic function, respectively.

Conclusions

Doppler tissue echocardiography and color M-mode Doppler flow could evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

Le texte complet de cet article est disponible en PDF.

Plan


 Supported in part by Grant NCC 9-60, National Aeronautics and Space Administration, Houston, Texas (J.D.T.), and a grant from Myocor Inc, Plymouth, Minn.


© 2003  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 16 - N° 5

P. 424-431 - mai 2003 Retour au numéro
Article précédent Article précédent
  • Incidence and characteristics of segmental postsystolic longitudinal shortening in normal, acutely ischemic, and scarred myocardium
  • Jens-Uwe Voigt, Gerd Lindenmeier, Bert Exner, Matthias Regenfus, Dierk Werner, Udo Reulbach, Uwe Nixdorff, Frank A Flachskampf, Werner G Daniel
| Article suivant Article suivant
  • Differential changes in regional right ventricular function before and after a bilateral lung transplantation: an ultrasonic strain and strain rate study
  • Virginija Dambrauskaite, Lieven Herbots, Piet Claus, Geert Verleden, Dirk Van Raemdonck, Marion Delcroix, George R Sutherland

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.