Addition of right-sided and posterior precordial leads during stress testing - 28/08/11

Doi : 10.1016/S0002-8703(03)00513-1 
Eric A Shry, MD a, , Robert E Eckart, DO a, James L Furgerson, MD a, Karl C Stajduhar, MD a, Richard A Krasuski, MD b
a Cardiology Division, Brooke Army Medical Center, San Antonio, Tex, USA 
b Cardiology Flight, Wilford Hall Medical Center, Lackland Air Force Base, Lackland, Tex, USA 

*Reprint requests: Eric A. Shry, MD, Cardiology Service MCHE-MDC, 3851 Roger Brooke Drive, Bldg. 3600, Brooke Army Medical Center, San Antonio, TX 78234-6200, USA.

Abstract

Background

Exercise treadmill testing has limited sensitivity for the detection of coronary artery disease, frequently requiring the addition of imaging modalities to enhance the predictive value of the test. Recently, there has been interest in using nonstandard electrocardiographic (ECG) leads during exercise testing.

Methods

We consecutively enrolled all patients undergoing exercise myocardial imaging with four additional leads recorded (V4R, V7, V8, and V9). The test characteristics of the 12-lead, the 15-lead (12-lead, V7, V8, V9), and the 16-lead (12-lead, V4R, V7, V8, V9) ECGs were compared with stress imaging in all patients. In the subset of patients who underwent angiography within 60 days of stress testing, these lead arrays were compared with the catheterization findings.

Results

There were 727 subjects who met entry criteria. The mean age was 58.5 ± 12.3 years, and 366 (50.3%) were women. Pretest probability for disease was high in 241 (33.1%), intermediate in 347 (47.7%), and low in 139 (19.1%). A total of 166 subjects had an abnormal 12-lead ECG during exercise. The addition of 3 posterior leads to the standard 12-lead ECG resulted in 7 additional subjects having an abnormal electrocardiographic response to exercise. The addition of V4R resulted in only 1 additional patient having an abnormal ECG during exercise. The sensitivity of the ECG for detecting ischemia as determined by stress imaging was 36.6%, 39.2%, and 40.0% (P = NS) for the 12-lead, 15-lead, and 16-lead ECGs, respectively. In those with catheterization data (n = 123), the sensitivity for determining obstructive coronary artery disease was 43.5%, 45.2%, and 45.2% (P = NS) for the 12-lead, 15-lead, and 16-lead ECGs, respectively. The sensitivity of imaging modalities was 77.4% when compared with catheterization.

Conclusions

In patients undergoing stress imaging studies, the addition of right-sided and posterior leads did not significantly increase the sensitivity of the ECG for the detection of myocardial ischemia. Additional leads should not be used to replace imaging modalities for the detection of coronary artery disease.

Le texte complet de cet article est disponible en PDF.

Plan


 The opinions and research contained herein are the private ones of the authors and are not to be considered as official or reflecting the views of the Department of the Army, Department of the Air Force, or the Department of Defense.


© 2003  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 146 - N° 6

P. 1090-1094 - décembre 2003 Retour au numéro
Article précédent Article précédent
  • Acetylcysteine in the prevention of contrast-induced nephropathy after coronary angiography
  • J.Bradley Oldemeyer, W.Paul Biddle, Richard L Wurdeman, Aryan N Mooss, Erica Cichowski, Daniel E Hilleman
| Article suivant Article suivant
  • Clinical profile of streptococcus agalactiae native valve endocarditis
  • María Jesús Rollán, José Alberto San Román, Isidre Vilacosta, Cristina Sarriá, Javier López, María Acuña, José Luis Bratos

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.