S'abonner

Utility of B-natriuretic peptide in the evaluation of left ventricular diastolic function: Comparison with tissue Doppler imaging recordings - 26/08/11

Doi : 10.1016/j.ahj.2004.02.016 
Gary S. Mak, BS a, Anthony DeMaria, MD a, Paul Clopton, MS b, Alan S. Maisel, MD a,
a Cardiology Division, Department of Medicine, University of California, San Diego, Calif, USA, and 
b Veterans Affairs Medical Center, San Diego, San Diego, Calif, USA. 

*Reprint requests: Alan S. Maisel, MD, Veterans Affairs Medical Center, Cardiology 111-A, 3350 La Jolla Village Drive, San Diego, CA 92161, USA.

Abstract

Background

Although Doppler echocardiography provides assessment of abnormal left ventricular (LV) diastolic filling dynamics, its inherent limitations suggest the need for additional measures of diastolic dysfunction. The ratio of mitral velocity to early diastolic velocity of the mitral annulus (E/E′) derived from tissue Doppler imaging is associated with the mean LV end diastolic pressure (LVEDP). Because data suggest that B-natriuretic peptide (BNP) reflects ventricular pressure, we hypothesized that BNP levels correlate with indices of LV diastolic function by tissue Doppler imaging.

Methods and results

Doppler recordings of the mitral inflow and tissue Doppler imaging of the mitral annulus were obtained in 108 patients referred for echocardiography. BNP levels were measured by a rapid immunoassay and blinded to cardiologists making the assessment of LV function. BNP levels were higher when elevated E/E′ ratios derived from tissue Doppler imaging were identified. Patients identified with elevated LVEDP, defined as E/E′ >15 (n = 16), had the highest BNP levels (463 ± 80 pg/mL). Those with normal LVEDP, as predicted by E/E′ <8 (n = 36), had a mean BNP concentration of 97 ± 27 pg/mL. Those with E/E′ of 8 to 15 (n = 48) had a mean BNP level of 122 ± 24 pg/mL. The area under the receiver-operating curve for BNP to detect E/E′ >15 was 0.89 (95% CI, 0.82 to 0.96; P < .001). A BNP value of 173 pg/mL had a sensitivity of 88%, a specificity of 82%, and an accuracy of 83% for predicting E/E′ >15.

Conclusions

BNP levels correlate with the E/E′ ratios from tissue Doppler imaging (r = 0.48) and can reliably provide estimation of LV filling pressures. Although BNP levels do not correlate well with E/E′ ratios across the full spectrum of values, the combination of BNP levels along with E/E′ ratios from tissue Doppler imaging may be a better predictor of elevated LV filling pressures in patients with suspected diastolic dysfunction.

Le texte complet de cet article est disponible en PDF.

Plan


© 2004  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 148 - N° 5

P. 895-902 - novembre 2004 Retour au numéro
Article précédent Article précédent
  • Impact of angiotensin-converting enzyme gene polymorphism on neurohormonal responses to high- versus low-dose enalapril in advanced heart failure
  • W.H.Wilson Tang, Randall H. Vagelos, Yin-Gail Yee, Michael B. Fowler
| Article suivant Article suivant
  • Systole-diastole mismatch in hypertrophic cardiomyopathy is caused by stress induced left ventricular outflow tract obstruction
  • Waleed Arshad, Alison M. Duncan, Darrel P. Francis, Christine A. O'Sullivan, Derek G. Gibson, Michael Y. Henein

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.