Background

Although clinical trials have found that enoxaparin clearance is prolonged in renal impairment, only one letter describes experience with adjusting doses. Only pharmacokinetic studies exist to guide dose adjustment in response to anti-Xa levels. Unfractionated heparin has comparable major bleeding in renal impairment compared with unadjusted enoxaparin. This necessitates a pharmacokinetic program to adjust enoxaparin with anti-Xa monitoring.

Methods

A pharmacokinetic program was created in response to adverse events and physician interest in a service. A program was designed providing all patients a loading dose of 1 mg/kg enoxaparin. Subsequent doses were 0.50 mg/kg per dose subcutaneously (SC) every 12 hours (q12h) for patients with a creatinine clearance (CrCl) ≤30 mL/min (severe group) and 0.75 mg/kg per dose SC q12h for patients with CrCl of 30 to 60 mL/min (moderate group). A 1-year review of 170 hospitalized patients is reported.

Results

The mean ± SD [95% CI] anti-Xa level 4 hours after the third dose was 0.65 ± 0.19 [0.59 to 0.70] IU/mL for the severe group and 0.82 ± 0.18 [0.79 to 0.85] IU/mL for the moderate group (P < .001). Eighty percent of patients with moderate renal failure and 60% of the patients with severe renal failure were in the therapeutic anti-Xa range after the third dose. A dose-adjustment ratio was used to adjust doses in patients whose levels were outside the therapeutic range: New dose = [(Current dose) × (Goal anti-Xa level)]/(Current anti-Xa level). An incidence of bleeding comparable to that found in normal patients was found.

Conclusions

In high-risk patients, it is reasonable to limit the exposure of patients to low molecular weight heparins by using anti-Xa levels as a marker. The enoxaparin protocol for renally impaired patients successfully placed patients in the therapeutic range established by consensus guidelines. The dose-adjustment ratio adds significant understanding to the pharmacokinetics of dose adjustment.

Le texte complet de cet article est disponible en PDF.

Plan


© 2004  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 148 - N° 4

P. 582-589 - octobre 2004 Retour au numéro
Article précédent Article précédent
  • Diagnostic value of serial measurement of cardiac markers in patients with chest pain: Limited value of adding myoglobin to troponin I for exclusion of myocardial infarction
  • Kai Marten Eggers, Jonas Oldgren, Anna Nordenskjöld, Bertil Lindahl
| Article suivant Article suivant
  • Adjunctive effect of hyperbaric oxygen treatment after thrombolysis on left ventricular function in patients with acute myocardial infarction
  • Milica Dekleva, Aleksandar Neskovic, Alja Vlahovic, Biljana Putnikovic, Branko Beleslin, Miodrag Ostojic

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.