Cardiovascular changes after extraglottic airway insertion: A prospective, randomized comparison between the laryngeal mask or the new PAXpress - 25/08/11

Doi : 10.1016/j.jclinane.2003.09.016 
Andrea Casati, MD a, * , Federico Vinciguerra, MD a, , Emanuela Spreafico, MD a, , Chiara Marchetti, MD a, , Marta Putzu, MD a, *, Rossella Siliotti, MD b, , Epifanio Mondello, MD a, §
a Vita-Salute University of Milan–Department of Anesthesiology, IRCCS H. San Raffaele, Milan, Italy 
b University of Messina, Department of Anesthesiology, Policlinico di Messina, Messina, Italy 

*Address corresponding to Dr. A. Casati at the Department of Anesthesiology, IRCCS H San Raffaele, Via Olgettina 60, 20132 Milan, Italy.

Abstract

Study objective

To compare hemodynamic responses induced with the new extraglottic airway, PAXpress, and the classic Laryngeal Mask Airway (LMA).

Design

Prospective, randomized study.

Setting

Anesthesia department of a university teaching hospital.

Patients

70 ASA physical status I and II patients, aged 18 to 65 years, scheduled to receive general anesthesia for extraabdominal procedures of short duration.

Interventions

Patients were randomly allocated to receive either a LMA (n = 35) or a PAXpress (n = 35) placement. After midazolam premedication (0.05 mg kg−1) and general anesthesia induction (propofol 2.5 mg kg−1, and fentanyl 1 μg kg−1) the airways were placed according to manufacturer instructions; then general anesthesia was maintained with a 2% sevoflurane concentration and an air/oxygen mixture.

Measurements and main results

Arterial blood pressure [both systolic (SBP) and diastolic (DBP)] and heart rate (HR) values were recorded immediately before airway placement, immediately after airway placement, then every 1 minute during the first 5 minutes. During the first 5 minutes after airway insertion, both SBP and DBP values were higher with the PAXpress than the LMA (repeated measures analysis of variance:p = 0.02 and p = 0.006, respectively), whereas no differences were reported in HR values. Also, the maximum percentage increase in both SBP and DBP values was larger with PAXpress [+19% (range: −19% to +80%) for SBP and +26% (range: −17% to +96%) for DBP] than the LMA [+9% (range: −30% to +90%) for SBP and +10% (range: −30% to +92%) for DBP] (p = 0.006 and p = 0.001, respectively).

Conclusions

Although further studies are required to evaluate safety and airway trauma of this new extraglottic airway, placing the PAXpress produces more marked changes in hemodynamic variables as compared with those produced by the LMA.

Le texte complet de cet article est disponible en PDF.

Keywords : Anesthesia, general, sevoflurane, airway, extraglottic: Laryngeal Mask Airway, PAXpress, monitoring, hemodynamic effects, arterial blood pressure


Plan


© 2004  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 16 - N° 5

P. 342-346 - août 2004 Retour au numéro
Article précédent Article précédent
  • Adverse events associated with the intraoperative injection of isosulfan blue
  • M.Denise Daley, Peter H. Norman, Jessie A. Leak, Dy T. Nguyen, Thao P. Bui, Alicia M. Kowalski, Una Srejic, Keyuri Popat, James F. Arens, Jeffrey E. Gershenwald, Kelly K. Hunt, Henry M. Kuerer
| Article suivant Article suivant
  • A noninvasive partial carbon dioxide rebreathing technique for measurement of pulmonary capillary blood flow is also a useful oxygenation monitor during one-lung ventilation
  • Shunsuke Fujii, Mutsuhito Kikura, Tomosue Takada, Shigeru Katoh, Nao Aoyama, Shigehito Sato

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.