S'abonner

Endoscopic submucosal dissection with electrosurgical knives in a patient on aspirin therapy (with video) - 24/08/11

Doi : 10.1016/j.gie.2010.06.008 
Andrew Y. Wang, MD , Fabian Emura, MD, PhD, Ichiro Oda, MD, Dawn G. Cox, RN, Hyun-soo Kim, MD, Paul Yeaton, MD
Current affiliations: Division of Gastroenterology and Hepatology (A.Y.W., D.G.C., P.Y.), Department of Medicine, University of Virginia, Charlottesville, Virginia, EmuraCenter LatinoAmerica (F.E.), Division of Gastroenterology (F.E.), Universidad de La Sabana, Bogotá, Colombia, Endoscopy Division (I.O.), National Cancer Center Hospital, Tokyo, Japan, Division of Gastroenterology and Hepatology (H.K.), Department of Internal Medicine, Daegu Fatima Hospital, Daegu, Republic of Korea 

Reprint requests: Andrew Y. Wang, MD, Division of Gastroenterology and Hepatology, Box 800708, University of Virginia Health System, Charlottesville, VA 22908

Résumé

Background

The electrosurgical knives required to perform endoscopic submucosal dissection (ESD) have recently passed the 510(k) premarketing evaluation by the U.S. Food and Drug Administration and are now available for purchase in the United States. Challenges to ESD being more widely performed in the United States include the lack of intensive hands-on training programs and a low incidence of appropriate, highly dysplastic gastric lesions on which an ESD-trained endoscopist can begin performing this procedure in patients. Furthermore, there are no guidelines regarding the safety of continuing antiplatelet therapy in patients undergoing ESD.

Objective

To report on the first gastric ESD performed in the United States by using recently approved electrosurgical knives on a patient who was maintained on aspirin therapy.

Design

Case report.

Setting

Large academic medical center.

Patient

One patient with a 2-cm high-grade dysplasia (HGD) lesion in the posterior antrum who had indwelling coronary stents and was maintained on aspirin therapy throughout the periprocedural period.

Interventions

High-definition white-light and narrow-band imaging endoscopy, endosonography, and ESD by using recently approved electrosurgical knives.

Main Outcome Measurements

Complete resection of the HGD gastric lesion.

Results

En bloc complete resection of the HGD gastric lesion was achieved without any immediate or delayed bleeding or perforation. No residual or recurrent dysplasia was found on 1- or 3-month follow-up endoscopies.

Limitations

Generalizations cannot be made from this single case.

Conclusions

After receiving intensive hands-on training in both ex vivo and in vivo animal models, gastric ESD was successfully performed by 2 U.S. endoscopists by using recently approved electrosurgical knives in a patient maintained on aspirin therapy without any complications.

Le texte complet de cet article est disponible en PDF.

Abbreviations : ESD, HGD, LGD, NBI


Plan


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: Dr. Emura: consultant for Olympus. Dr. Yeaton: consultant for Olympus and Gore. The other authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Wang at ayw7d@virginia.edu.


© 2010  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 72 - N° 5

P. 1066-1071 - novembre 2010 Retour au numéro
Article précédent Article précédent
  • Cavernous hemangiomas limited to the sigmoid colon
  • Sónia Leite, Ricardo Veloso, Rolando Pinho, Ana Paula Silva, Joana Pinto, Miguel Afonso, Joao Carvalho, Jose Fraga
| Article suivant Article suivant
  • Mortality after percutaneous endoscopic gastrostomy in patients with cirrhosis: a case series
  • Joseph G. Baltz, Curtis K. Argo, Abdullah M.S. Al-Osaimi, Patrick G. Northup

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.