S'abonner

A novel perfusion imaging technique of the pancreas: contrast-enhanced harmonic EUS (with video) - 23/08/11

Doi : 10.1016/j.gie.2007.07.045 
Masayuki Kitano, MD, PhD , Hiroki Sakamoto, MD, PhD, Uwe Matsui, MD, PhD, Yasuhiro Ito, BSc, Kiyoshi Maekawa, RMS, Tammo von Schrenck, MD, PhD, Masatoshi Kudo, MD, PhD
Current affiliations: Division of Gastroenterology and Hepatology (M. Kitano, H.S., M. Kudo), Department of Internal Medicine, Section of Abdominal Ultrasound (K.M.), Kinki University School of Medicine, Osaka-Sayama, Japan, Department of Medicine (U.M., T.V.S.), Bethesda General Hospital Bergedorf, Hamburg, Germany, Research and Development (Y.I.), Aloka Co Ltd, Tokyo, Japan 

Reprint requests: Masayuki Kitano, MD, Division of Gastroenterology and Hepatology, Department of Internal Medicine, Kinki University School of Medicine, 377-2 Ohno-higashi, Osaka-sayama 589-8511, Japan.

Osaka-sayama, Japan, Hamburg, Germany

Abstract

Background

Contrast-enhanced harmonic-imaging techniques have been unavailable for EUS because of the limited frequency bandwidth and acoustic power output of current echoendoscopes.

Objective

To investigate the contrast harmonic imaging technique by using a prototype echoendoscope equipped with an adequate broad-band transducer that can detect harmonic signals from the US contrast agents.

Design

Identification of optimal settings (study I) and preliminary clinical investigations (study II).

Setting

Bethesda General Hospital Bergedorf.

Patients

A total of 104 patients undergoing standard EUS examinations.

Interventions

Contrast-enhanced harmonic EUS (CEH-EUS) was performed by using a prototype echoendoscope and extended pure harmonic detection mode, a specific mode for contrast harmonic imaging.

Main Outcome Measurements

In study I, time-intensity curves for peak signal intensity were calculated after infusion of a contrast agent, SonoVue, and the changes in echo intensity were compared for different mechanical indices and interval times. In study II, intermittent and real-time continuous images of pancreatobiliary and gastroduodenal diseases obtained by CEH-EUS were evaluated in comparison with contrast-enhanced power-Doppler EUS (CED-EUS).

Results

In study I, with the optimal mechanical index (0.4), homogeneous parenchymal perfusion images of the pancreas were obtained by intermittent imaging, and finely branching vessels of the pancreas were obtained with real-time continuous imaging. In study II, apparent perfusion and vessel images were observed in pancreatobiliary carcinomas, GI stromal tumors, and lymph-node metastases. CED-EUS failed to depict images of the fine vessels and parenchymal perfusion.

Limitations

The subjective nature of the findings, with a limited number of patients.

Conclusions

CEH-EUS successfully visualized parenchymal perfusion and microvasculature in the pancreas and may play an important role in the differential diagnosis of digestive diseases.

Le texte complet de cet article est disponible en PDF.

Abbreviations : CED-EUS, CEH-EUS, E-PHD, GIST, IV, MI, ROI


Plan


© 2008  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 67 - N° 1

P. 141-150 - janvier 2008 Retour au numéro
Article précédent Article précédent
  • EUS-guided drainage of bilomas: a new alternative?
  • Vanessa M. Shami, Jayant P. Talreja, Anshu Mahajan, Melissa S. Phillips, Paul Yeaton, Michel Kahaleh
| Article suivant Article suivant
  • A rare case of upper GI bleeding: esophageal rupture associated with thoracic aortic aneurysm
  • Tiing Leong Ang, Kieron Lim, Andrew Kwek, Eng Kiong Teo, Kwong Ming Fock

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.