Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy - 23/08/11

Doi : 10.1016/j.gie.2007.10.063 
Juan M. Herrerias, MD, Jonathan A. Leighton, MD, Guido Costamagna, MD, Anthony Infantolino, MD, Rami Eliakim, MD, Doron Fischer, MD, David T. Rubin, MD, Howard D. Manten, MD, Eitan Scapa, MD, Douglas R. Morgan, MD, MPH, Ari J. Bergwerk, MD , Binyamin Koslowsky, MD, Samuel N. Adler, MD
Current affiliations: Hospital Virgen de la Macarena (J.M.H.), Seville, Spain, Mayo Clinic Arizona (J.A.L.), Scottsdale, Arizona, USA, Universita Cattolica del Sacro Cuore (G.C.), Rome, Italy, Thomas Jefferson University (A.I.), Philadelphia, Pennsylvania, USA, Rambam Medical Center (R.E., D.F.), Haifa, Israel, University of Chicago (D.T.R.), Chicago, Illinois, USA, University of Miami (H.D.M.), Miami, Florida, USA, Assaf Harofeh Medical Center (E.S.), Zerifin, Israel, University of North Carolina at Chapel Hill (D.R.M.), Chapel Hill, North Carolina, USA, Shaare Zedek Medical Center (A.B.), Jerusalem, Israel, Bikur Holim Hospital (B.K., S.N.A.), Jerusalem, Israel 

Reprint requests: Ari J. Bergwerk, MD, Gastroenterology Institute, Shaare Zedek Medical Center, Jerusalem 91031, Israel.

Seville, Spain, Rome, Italy, Haifa, Zerifin, Jerusalem, Israel, Scottsdale, Arizona, Philadelphia, Pennsylvania, Chicago, Illinois, Miami, Florida, Chapel Hill, North Carolina, USA

Abstract

Background

Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention.

Objective

Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE.

Design

Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed.

Setting

International multicenter study.

Patients

A total of 106 patients with known strictures.

Intervention

Agile patency system.

Main Outcome Measurements

Performance and safety of Agile patency system.

Results

A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events.

Conclusions

These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.

Le texte complet de cet article est disponible en PDF.

Abbreviations : CE, RFID, SBFT


Plan


 See CME section; p. 932.


© 2008  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 67 - N° 6

P. 902-909 - mai 2008 Retour au numéro
Article précédent Article précédent
  • Double-balloon enteroscopy: ready for prime time?
  • Ahmad Kamal
| Article suivant Article suivant
  • A systematic review and meta-analysis of randomized, controlled trials of moderate sedation for routine endoscopic procedures
  • Kenneth R. McQuaid, Loren Laine

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.