S'abonner

Magnetic Resonance Imaging Is a Complementary Method to Stereological Measurement of Testicular Volume - 22/08/11

Doi : 10.1016/j.urology.2008.02.058 
Sahin Kabay a, , Mehmet Yucel a, Hilmi Ozden b, Faik Yaylak c, Orhan Ozbek d, Yakup Gumusalan e
a Department of Urology, Dumlupinar University Faculty of Medicine, Kutahya, Turkey 
c Department of General Surgery, Dumlupinar University Faculty of Medicine, Kutahya, Turkey 
d Department of Radiology, Dumlupinar University Faculty of Medicine, Kutahya, Turkey 
b Department of Anatomy, Osmangazi University Faculty of Medicine, Eskisehir, Turkey 
e Department of Anatomy, Kahramanmaras Sutcu Imam University Faculty of Medicine, Kahramanmaras, Turkey 

Reprint requests: Dr. Sahin Kabay, Department of Urology, Dumlupinar University, 43100 Kutahya, Turkey

Résumé

Objectives

The objective of our research was to determine the accuracy and precision of the Cavalieri principle with images obtained from magnetic resonance imaging (MRI) in estimation of the actual testicular volume in humans.

Methods

We performed volume measurements of 42 testes from 21 patients scheduled for bilateral orchiectomy for prostate cancer. We performed volume estimation measurements with ultrasonography (US), Prader's orchidometer (PrOM), and Cavalieri principle MRI (we used views in axial sagittal and planes) before orchiectomy. We measured actual testes volume with the fluid displacement technique after orchiectomy. Differences and correlations between estimated and actual volumes were evaluated. For all patients, we compared right and left testicular volumes independently with these measurements.

Results

Mean ± SD actual testicular volume and estimated testicular volumes with US, PrOM, and Cavalieri principle using MRI axial and sagittal images were 15.3 ± 3.3 and 17.7 ± 3.0 cm3, 20.0 ± 3.5 cm3, and 16.0 ± 3.7 and 16.0 ± 3.6 cm3, respectively. Estimated and measured volumes were not different from each other. US and PrOM measured volumes were correlated with the actual volume. However, r-values with Pearson correlation test for estimated volumes measured with the Cavalieri principle with MRI were higher than US and PrOM (r-values were 0.934 and 0.961 vs 0.919 and 0.757, respectively).

Conclusions

The results of this study demonstrate that testicular volume measurements with the Cavalieri principle using images obtained from MRI may be considered a complementary method to traditional techniques to estimate the actual testicular volume.

Le texte complet de cet article est disponible en PDF.

Plan


© 2009  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 73 - N° 5

P. 1131-1135 - mai 2009 Retour au numéro
Article précédent Article précédent
  • The Effect of Ischemia/Reperfusion on Rabbit Bladder—Role of Rho-kinase and Smooth Muscle Regulatory Proteins
  • Yung-Shun Juan, Suning Li, Robert M. Levin, Barry A. Kogan, Catherine Schuler, Robert E. Leggett, Chun-Hsiung Huang, Anita Mannikarottu
| Article suivant Article suivant
  • Effects of Exogenous Glutamate and Kainate on Electric Field-stimulated Contractions of Isolated Human Ureter
  • Slobodan M. Jankovic, Snezana V. Jankovic, Dobrivoje Stojadinovic, Miroslav Stojadinovic, Vladimir Kostovic, Milan Novakovic, Veroljub Markovic

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.