A semiautomated ultrasound border detection program that facilitates clinical measurement of ultrasound carotid intima-media thickness - 21/08/11

Doi : 10.1016/j.echo.2004.12.002 
James H. Stein, MD *, , Claudia E. Korcarz, DVM, RDCS *, Maureen E. Mays, MD, MS *, Pamela S. Douglas, MD *, Mari Palta, PhD , Hongling Zhang, MS , Tamara LeCaire, MS , Diane Paine, MED, RDCS §, David Gustafson, PhD §, Liexiang Fan, PhD §
* Atherosclerosis Imaging Research Program, Section of Cardiovascular Medicine, Madison, Wisconsin 
 Department of Population Health Sciences, University of Wisconsin Medical School, Madison, Wisconsin 
§ Siemens Medical Solutions, Issaquah, Washington 

Reprint requests: James H. Stein, MD, Department of Medicine, Section of Cardiovascular Medicine, University of Wisconsin Medical School, 600 Highland Avenue, G7/341 CSC (MC 3248), Madison, WI 53792

Résumé

We have developed a novel, semiautomated carotid intima-media thickness (CIMT) border detection program (AUTO) and evaluated its measurement reproducibility and accuracy. Images from 6 carotid segments were acquired in 50 subjects, for a total of 300 segments. Mean and maximum CIMT values were measured blindly at a reference (REF) lab and in duplicate by experienced (EXP) and novice (NOV) readers using manual (MAN) and AUTO methods. Coefficients of variation for AUTO measurements of mean (3.2%) and maximum (4.1%) CIMT were low, and the AUTO method improved the NOV reader’s reproducibility. Compared with the REF lab, mean (0.012 ± 0.006 mm) and maximum (0.144 ± 0.006 mm) CIMT biases were small and equivalent to those of the REF lab (P < .001). The AUTO method shortened reading times by 35% to 46% (P < .001). We conclude that our novel AUTO CIMT measurement program improved reproducibility and was accurate. Compared with MAN tracing, the AUTO method agreed better with the REF lab and decreased reading time.

Le texte complet de cet article est disponible en PDF.

Plan


 Supported by a grant from Siemens Medical Solutions. Dr. Stein was supported by the National Center for Research Resources (grant K23 RR16176), receives research support from Siemens Medical Solutions, and is a consultant to Camtronics Medical Systems and Sonosite, Inc. Dr. Stein, Dr. Palta, Ms. Zhang, and Ms. LeCaire also received funding from the National Heart, Lung, and Blood Institute (grant R01 HL62897). Dr. Mays was supported by National Institutes of Health National Service Award T32 HL07936, from the University of Wisconsin-Madison Cardiovascular Research Center. Ms. Paine, Dr. Gustafson, and Dr. Fan are employees of Siemens Medical Solutions.


© 2005  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 18 - N° 3

P. 244-251 - mars 2005 Retour au numéro
Article précédent Article précédent
  • Anatomoechocardiographic correlation double inlet left ventricle
  • Luis Muñoz-Castellaños, Nilda Espinola-Zavaleta, Candace Keirns
| Article suivant Article suivant
  • Doppler echocardiography of 119 normal-functioning St Jude Medical mitral valve prostheses: A comprehensive assessment including time-velocity integral ratio and prosthesis performance index*
  • Joseph F. Malouf, Manfredi Ballo, Heidi M. Connolly, David O. Hodge, Regina M. Herges, Charles J. Mullany, Fletcher A. Miller

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.